Parameter list
01.04
11-82
SIEMENS AG 6SG7000-0BA76
SIMOTRAS HD Operating Instructions
PNU
Description
Value range
[Unit]
No. indices See
Change
U101
(2101)
*
S00
(B115)
Source for the activation of F024 and F020
FB 3, FB 287
Selection of the binectors that activate fault messages F024 or F020 on log.
"1"
0 = Binector B0000
1 = Binector B0001
etc.
Up to SW 1.7: F024 (without fault value) if binector = 1 (FB 3)
SW 1.8 and later:
i001: F024 with fault value 1 (FB 3)
i002: F024 with fault value 2
i003: F024 with fault value 3
i004: F024 with fault value 4
i005: F020 with fault value 1 (FB 287)
i006: F020 with fault value 2
i007: F020 with fault value 3
i008: F020 with fault value 4
All binector numbers
1
Ind: 8
FS=
i001: 9582
i002: 0
i003: 0
i004: 0
i005: 0
i006: 0
i007: 0
i008: 0
Type: L2
P052 = 3
P051 = 40
Offline
U102
(2102)
*
S00
(B115)
Source for the activation of F033 and F053
FB 4, FB 288
Selection of the binectors that activate fault messages F033 or F053 on
log. "1"
0 = Binector B0000
1 = Binector B0001
etc.
Up to SW 1.7: F033 (without fault value) if binector = 1 (FB 4)
SW 1.8 and later:
i001: F033 with fault value 1 (FB 4)
i002: F033 with fault value 2
i003: F033 with fault value 3
i004: F033 with fault value 4
i005: F053 with fault value 1 (FB 288)
i006: F053 with fault value 2
i007: F053 with fault value 3
i008: F053 with fault value 4
All binector numbers
1
Ind: 8
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U103
(2103)
*
S00
(B115)
Source for the activation of F034 and F054
FB 5, FB 289
Selection of the binectors that activate fault messages F034 or F054 on log.
"1"
0 = Binector B0000
1 = Binector B0001
etc.
Up to SW 1.7: F034 (without Fault value) if binector = 1 (FB 5)
SW 1.8 and later:
i001: F034 with fault value 1 (FB 5)
i002: F034 with fault value 2
i003: F034 with fault value 3
i004: F034 with fault value 4
i005: F054 with fault value 1 (FB 289)
i006: F054 with fault value 2
i007: F054 with fault value 3
i008: F054 with fault value 4
All binector numbers
1
Ind: 8
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U104
(2104)
*
S00
(B115)
Source for the activation of A023 and A019
FB 6, FB 256
Selection of the binectors that activate alarm A023 or A019 on log. "1"
0 = Binector B0000
1 = Binector B0001
etc.
Up to SW 1.7: A023
(FB 6)
SW 1.8 and later:
i001:
A023 (FB
6)
i002:
A019 (FB
256)
All binector numbers
1
Ind: 2
FS=
i001: 9552
i002: 0
Type: L2
P052 = 3
P051 = 40
Offline
Summary of Contents for SIMOTRAS 6SG7050
Page 8: ...Contents 01 04 0 6 Siemens AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 12: ...Safety information 01 04 1 4 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 30: ...Description 01 04 3 14 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 32: ...Shipment unpacking 01 04 4 2 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 46: ...Installation 01 04 5 14 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 142: ...Start up 01 04 7 56 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 298: ...Function diagrams 01 04 8 156 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 330: ...Function descriptions 01 04 9 32 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 348: ...Faults alarms 01 04 10 18 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 510: ...Parameter list 01 04 11 162 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 580: ...Maintenance 01 04 13 10 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 586: ...Servicing Spare parts 01 04 14 6 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 600: ...Appendix 01 04 18 4 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 602: ...Appendix 01 04 18 6 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 603: ......