01.04
Start-up
SIEMENS AG 6SG7000-0BA76
7-11
SIMOTRAS HD Operating Instructions
7.6.8
Setting the current controller loop
Formula:
The factory setting for the current controller parameter can normally be left as it is:
P155 = Kp = 0.2 P156 = Tn = 20 ms
Optimizing the current controller:
With the motor fully braked, enter the current setpoint increments and record the step response
from the current controller loop.
Rotor stage S1 is active
•
Fully brake the motor and interrupt the supply voltage to the brake contactor.
•
P084 = 2 (current-controlled operation)
current setpoint from square wave generator (P500 = 203, factory setting)
•
Parameterize square wave generator:
P480 = 20,0 % (step level 1)
P481 = 1.0 s (duration of step)
P482 = 10.0 % (step level 2)
P483 = 1.0 s (duration of step)
•
Enter first setpoint stage from master switch (i.e. a travel command).
•
Trace the stator current on the actual current value output (X175 terminals 12 and 13, 5V is the
rated current for the SIMOTRAS HD) using an oscilloscope. The oscillogram will display the step
response of the current controller loop.
t
t
Current setpoint
Actual current value
•
The following settings affect the current controller loop:
P155 Controller gain Kp
P156 Reset time Tn
The control response becomes “softer” if a longer reset time is set.
•
Move master switch to zero position (i.e. cancel travel command).
•
Following current controller optimization:
P084 = 1 (reset to operation under closed-loop speed control)
•
Reconnect power supply to brake contactor.
Summary of Contents for SIMOTRAS 6SG7050
Page 8: ...Contents 01 04 0 6 Siemens AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 12: ...Safety information 01 04 1 4 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 30: ...Description 01 04 3 14 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 32: ...Shipment unpacking 01 04 4 2 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 46: ...Installation 01 04 5 14 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 142: ...Start up 01 04 7 56 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 298: ...Function diagrams 01 04 8 156 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 330: ...Function descriptions 01 04 9 32 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 348: ...Faults alarms 01 04 10 18 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 510: ...Parameter list 01 04 11 162 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 580: ...Maintenance 01 04 13 10 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 586: ...Servicing Spare parts 01 04 14 6 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 600: ...Appendix 01 04 18 4 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 602: ...Appendix 01 04 18 6 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 603: ......