Start-up
01.04
7-10
SIEMENS AG 6SG7000-0BA76
SIMOTRAS HD Operating Instructions
7.6.5 Actual speed sensing data
7.6.5.1 Operation with pulse encoder
(often present when retrofitting existing systems)
P083 = 2: The actual speed is supplied by the pulse encoder (K0040)
P140 = 1. Pulse encoder type 1
Encoder with two pulse tracks mutually displaced by 90°
Track 1
X173 28, 29
Track 2
X173 30, 31
P141
Number of pulses of pulse encoder (pulses per revolution)
P142 = 1: Pulse encoder outputs 15V signals
NOTICE
Resetting parameter P142 to the alternative setting does not switch over the supply
voltage for the pulse encoder (terminals X173.26 and 27).
Terminal X173.26 always su15V. An external voltage supply must be
provided for pulse encoders requiring a 5V supply.
P143
Setting the maximum speed for pulse encoder operation (in pulses/rev)
The speed set in this parameter corresponds to an actual speed (K0040) of 100%.
7.6.5.2 Operation with analog tacho
(used in new systems)
P083 = 1: The actual speed is supplied from the “Main actual value” channel (K0013)
(terminals XT.103, XT.104)
P741
Setting of tachometer voltage at maximum speed (approx. 8V to +270.00V)
7.6.6
Speed setpoint data
7.6.6.1 Operation with analog setpoint (U251=0)
P700 = 0: Voltage input (+-10V)
1: Current input (0 to 20 mA)
2: Current input (4 to 20 mA)
P401 Normalization
speed setpoint that must be attained under control by master switch (in %).
with lifting gear: approx. 60%
with travel gear: up to 100%
Note: Limit value for zero-delay angle (U628), see also Section 7.6.14
7.6.6.2 Operation with 4 stage master switch (U251=1)
U251=1: Use setpoint of 4-stage master switch
U665
speed setpoint in “slow” stage
factory setting 10%
U666
speed setpoint in “medium” stage
factory setting 25%
U667
speed setpoint in “fast” stage
factory setting 40%
U668
speed setpoint in “full” stage
factory setting 100%
7.6.7 Selection of basic technological functions
Current limits
P171
System current limit in torque direction I (in% of P100)
P172
System current limit in torque direction II (in% of P100)
Summary of Contents for SIMOTRAS 6SG7050
Page 8: ...Contents 01 04 0 6 Siemens AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 12: ...Safety information 01 04 1 4 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 30: ...Description 01 04 3 14 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 32: ...Shipment unpacking 01 04 4 2 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 46: ...Installation 01 04 5 14 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 142: ...Start up 01 04 7 56 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 298: ...Function diagrams 01 04 8 156 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 330: ...Function descriptions 01 04 9 32 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 348: ...Faults alarms 01 04 10 18 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 510: ...Parameter list 01 04 11 162 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 580: ...Maintenance 01 04 13 10 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 586: ...Servicing Spare parts 01 04 14 6 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 600: ...Appendix 01 04 18 4 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 602: ...Appendix 01 04 18 6 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 603: ......