Parameter list
01.04
11-104
SIEMENS AG 6SG7000-0BA76
SIMOTRAS HD Operating Instructions
PNU
Description
Value range
[Unit]
No. indices See
Change
U288
(2288)
S00
(B160)
x values
i001
1st characteristic point
for FB108
i002
2nd characteristic point for FB108
...
i010
10th characteristic point for FB108
SW 1.8 and later:
i011
1st characteristic point
for FB284
i012
2nd characteristic point for FB284
...
i020
10th characteristic point for FB284
i021
1st characteristic point
for FB285
i022
2nd characteristic point for FB285
...
i030
10th characteristic point for FB285
-200.00 to 199.99
[%]
0.01
Ind: 30
FS=0.00
Type: I2
P052 = 3
P051 = 40
Online
U289
(2289)
S00
(B160)
y values
i001
1st characteristic point
for FB108
i002
2nd characteristic point for FB108
...
i010
10th characteristic point for FB108
SW 1.8 and later:
i011
1st characteristic point
for FB284
i012
2nd characteristic point for FB284
...
i020
10th characteristic point for FB284
i021
1st characteristic point
for FB285
i022
2nd characteristic point for FB285
...
i030
10th characteristic point for FB285
-200.00 to 199.99
[%]
0.01
Ind: 30
FS=0.00
Type: I2
P052 = 3
P051 = 40
Online
Dead zones
The component of the input quantity (x) whose absolute value exceeds the threshold for the dead zone is applied to the output (y).
Dead zone 1
(output = K9232)
U290
(2290)
*
S00
(B161)
Source for input quantity
FB 109
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U291
(2291)
S00
(B161)
Dead zone
FB 109
0.00 to 100.00
[%]
0.01
Ind: None
FS=0.00
Type: O2
P052 = 3
P051 = 40
Online
Dead zone 2
(output = K9233)
U292
(2292)
*
S00
(B161)
Source for input quantity
FB 110
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U293
(2293)
S00
(B161)
Dead zone
FB 110
0.00 to 100.00
[%]
0.01
Ind: None
FS=0.00
Type: O2
P052 = 3
P051 = 40
Online
Dead zone 3
(output = K9234)
U294
(2294)
*
S00
(B161)
Source for input quantity
FB 111
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U295
(2295)
S00
(B161)
Dead zone
FB 111
0.00 to 100.00
[%]
0.01
Ind: None
FS=0.00
Type: O2
P052 = 3
P051 = 40
Online
Summary of Contents for SIMOTRAS 6SG7050
Page 8: ...Contents 01 04 0 6 Siemens AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 12: ...Safety information 01 04 1 4 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 30: ...Description 01 04 3 14 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 32: ...Shipment unpacking 01 04 4 2 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 46: ...Installation 01 04 5 14 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 142: ...Start up 01 04 7 56 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 298: ...Function diagrams 01 04 8 156 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 330: ...Function descriptions 01 04 9 32 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 348: ...Faults alarms 01 04 10 18 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 510: ...Parameter list 01 04 11 162 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 580: ...Maintenance 01 04 13 10 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 586: ...Servicing Spare parts 01 04 14 6 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 600: ...Appendix 01 04 18 4 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 602: ...Appendix 01 04 18 6 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 603: ......