Faults / alarms
01.04
10-14
SIEMENS AG 6SG7000-0BA76
SIMOTRAS HD Operating Instructions
Fault
Description
No.
Cause as a function of fault value
(r047.001, r949.001 or r949.009 with acknowledged error)
Further information (r047.002 to r047.016)
5
Parameters P918, U711 to U721 are not correctly set or
not accepted after a change by means of U710 = 0
setting. (The meanings of these parameters are defined
in the manual for the relevant CB board, see also
function diagrams, Section 8, Sheets Z110 and Z111)
i015 Code number of board:
1
TB
or
1
st
CB
2
2
nd
CB
6
The initialization run for a CB/TB board has not been
completed within 40 s
i015 Code number of board:
1
TB
or
1
st
CB
2
2
nd
CB
F081 CB/TB
heartbeat
error
CB/TB has not incremented the monitoring counter for a period
of 800 ms
Possible causes of fault
•
CB/TB board is defective
•
CB/TB board is not correctly inserted
i015 Code number of board:
1
TB
or
1
st
CB
2
2
nd
CB
F082
CB/TB message timeout or error in data exchange
Possible causes of fault
•
CB/TB PZD message timeout (with fault value 10)
•
Excessive EMC-related interference
(e.g. due to unprotected contactors, unscreened cables, loose screen connections)
•
CB/TB board is defective
•
CB/TB board is not correctly inserted
Fault value:
r047 Index 002 to 016:
1
Fault in alarm channel from CB to basic unit
i015 Code number of board:
1
TB
or
1
st
CB
2
2
nd
CB
2
Fault in alarm channel from TB to basic unit
3
Fault in fault channel from TB to basic unit
5
Fault in parameter job channel from CB to basic unit
i015 Code number of board:
1
TB
or
1
st
CB
2
2
nd
CB
6
Fault in parameter response channel from basic unit to
CB
i015 Code number of board:
1
1. TB or 1
st
CB
2
2
nd
CB
7
Fault in parameter job channel from TB to basic unit
8
Fault in parameter response channel from basic unit to
TB
10
CB/TB process data failure (message timeout period set
in U722)
i015 Code number of board:
1
TB
or
1
st
CB
2
2
nd
CB
11
Fault in parameter job channel from PMU to TB
12
Fault in parameter response channel from TB to PMU
15
Fault in setpoint channel from CB/TB to basic unit
i015 Code number of board:
1
TB
or
1
st
CB
2
2
nd
CB
16
Fault in actual value channel from basic unit to CB/TB
i015 Code number of board:
1
TB
or
1
st
CB
2
2
nd
CB
10.1.2.12 Fault messages from supplementary boards
F101
to
F147
This group of fault messages is activated by supplementary boards
Please refer to the operating manual of the relevant supplementary board for explanation of the fault messages and fault values
Summary of Contents for SIMOTRAS 6SG7050
Page 8: ...Contents 01 04 0 6 Siemens AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 12: ...Safety information 01 04 1 4 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 30: ...Description 01 04 3 14 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 32: ...Shipment unpacking 01 04 4 2 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 46: ...Installation 01 04 5 14 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 142: ...Start up 01 04 7 56 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 298: ...Function diagrams 01 04 8 156 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 330: ...Function descriptions 01 04 9 32 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 348: ...Faults alarms 01 04 10 18 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 510: ...Parameter list 01 04 11 162 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 580: ...Maintenance 01 04 13 10 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 586: ...Servicing Spare parts 01 04 14 6 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 600: ...Appendix 01 04 18 4 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 602: ...Appendix 01 04 18 6 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 603: ......