Maintenance
01.04
13-2
SIEMENS AG 6SG7000-0BA76
SIMOTRAS HD Operating Instructions
13.1 Procedure for updating software
(upgrading to a new software version)
1
Read out and write down all parameter
contents.
(also note software version in r060.001 and
r065.001!)
Note:
The parameter set can be transferred to a PC or
programming device by means of DriveMonitor
(see also Section 15).
2
Switch off electronics power supply
3
Connect one COM port on the PC to
connector X300 on the converter
Cable order number:
6SX7005-0AB00
(see also Section 15.3)
4
Switch on electronics power supply AND press
down the UP key on the PMU of the
SIMOTRAS HD converter at the same time
⇒
The SIMOTRAS HD converter switches to
operating state o13.0
Note:
A software update can be started only from the
PMU panel and not via an OP1S or the
DriveMonitor system
5
Open a DOS window on the PC and enter
program call:
HEXLOAD 7001Axxx.H86 7001Bxxx.H86 COMx
Start the program by pressing Return
⇒
The software update is performed
automatically
Note:
HEXLOAD.EXE: Loading
program
7001Axxx.H86 and 7001Bxxx.H86:
Data files which contain the SIMOTRAS software
xxx is the SW release
COMx: COM1 or COM2
6
⇒
When the software has been updated
successfully, the SIMOTRAS HD switches
to operating state o13.2 for approx. 1 s
⇒
The SIMOTRAS HD converter then
switches to operating state o12.9 in many
cases (depending on which SW version
was previously installed in the converter)
for approximately 15s.
Note:
The currently programmed addressed is displayed
on the PMU while the update is in progress
The current status of the update routine is
displayed on the PC
7
Check the checksum:
Comparison of the value of parameter r062.001 with the checksum in the Internet under menu item
"Info" (see the inside page of the cover sheet of the operation instructions).
8
Was the electronics supply disconnected while
Step 6 was in progress?
?
yes
9b
Acknowledge any fault message that may
appear on the SIMOTRAS HD device
n
o
10b
Restore default setting
(see Section 7.4)
11b
Start up the converter again
(see Section 7.5)
Note:
The parameter set stored in Step 1 above can
be loaded from a PC or programming device
by means of DriveMonitor.
12
End
Summary of Contents for SIMOTRAS 6SG7050
Page 8: ...Contents 01 04 0 6 Siemens AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 12: ...Safety information 01 04 1 4 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 30: ...Description 01 04 3 14 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 32: ...Shipment unpacking 01 04 4 2 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 46: ...Installation 01 04 5 14 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 142: ...Start up 01 04 7 56 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 298: ...Function diagrams 01 04 8 156 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 330: ...Function descriptions 01 04 9 32 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 348: ...Faults alarms 01 04 10 18 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 510: ...Parameter list 01 04 11 162 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 580: ...Maintenance 01 04 13 10 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 586: ...Servicing Spare parts 01 04 14 6 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 600: ...Appendix 01 04 18 4 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 602: ...Appendix 01 04 18 6 SIEMENS AG 6SG7000 0BA76 SIMOTRAS HD Operating Instructions ...
Page 603: ......