7 Drive Machine Data (SIMODRIVE Drive MD)
07.97
7.3.2 Drive MD (data description)
Format of power section code number:
Value table:
Code
Drive type
Current
PS
Comments
6
MSD
24/32/32 A
50 A
7
MSD
30/40/51 A
80 A
8
MSD
45/60/76 A
120 A
9
MSD
60/80/102 A
160 A
A
MSD
85/110/127 A
200 A
B
MSD
120/150/193 A
300 A
C
MSD
200/250/257 A
400 A
D
MSD
45/60/76 A
108 A
11
FDD
3/6 A
8 A
12
FDD
5/10 A
15 A
14
FDD
9/18 A
25 A
16
FDD
18/36 A
50 A
17
FDD
28/56 A
80 A
19
FDD
56/112 A
160 A
1A
FDD
70/140 A
200 A
28
FDD
140/210 A
400 A
as from SW 4.1
Transistor limit current, power section
1107
Default value
Lower input limit
Upper input limit
Units
200.0
1.0
500.0
A
Active on
Power On
Input of maximum permissible current of power section. This machine data is automatically
parameterized for Siemens power sections by the machine data "Power section code"
(MD 1106).
Caution:
This data serves as the basis for normalizing the current actual value sensor and must not be
changed by the user after automatic presetting of its values.