12 Functional Descriptions
01.99
12.19.5 Interpolation and compensation with tables
5. Deactivate and retract
N0250 @40c K11 K2 K0
- Deactivate IKA 2
@714
G200 Y
- Synchronization of actual value system
N0255 G0 Y200
- Retract
N0260 X300
N0270 @100 K300
Jump to end
6. Errors
N0281 M00 (error 1)
T55=1: only one pointer <> 0 !
@100 K300
N0282 M00 (error 2)
T55=2: End pointer <= start pointer!
@100 K300
N0283 M00 (error 3)
T55=3: Input[n+1] <= input[n] !
N0285 @30c R31 K56 K1
- Read current point number n [> R31]
@100 K300
N0284 M00 (error 4)
T55=4: Gradient > 1 !
N0285 @30c R31 K56 K1
- Read current point number n [> R31]
7. End
N0300 M02
IKA status displays in T55 and T66
Code
Text
Significance
-2
Running
Calculation running
-1
Requested
Calculation requested
0
Calculated
Curve calculated
1
0 pointer
Start or end pointer is equal to zero
2
Start > End
Start pointer is greater than stop pointer
3
Position point
The position of one point is wrong
4
Gradient point
Gradient of one point is wrong.
The point is then stored in T56.
5
Both pointers in the table are zero.
12–198
© Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)
Summary of Contents for SIMODRIVE 611-D