7 Drive Machine Data (SIMODRIVE Drive MD)
09.95
7.4.3 Diagnosis/service MD (data description - as from SW 3)
Status word 1
11004
Default value
Lower output limit
Upper output limit
Units
–
0000
FFFF
Hex
Active
after ramp-up
of 611D link
This machine data contains the low-order status bits (bits 0-15) of the cyclical status word at
the interface between SERVO and 611D.
Bit 0
DC link 1 reset
Bit 1
Parking axis setpoint
0 : on
1 : off
Bits 2-4
Assigned to or reserved for internal system functions
Bit 5
Function generator setpoint
0 : on
1 : off
Bit 6
Assigned to or reserved for internal system functions
Bit 7 - SW 4
Ramp-function generator setpoint
0 : on
1 : off
Bit 8
Assigned to or reserved for internal system functions
Bit 9
Bit 10
Bit 11
Ramp-function generator rapid stop setpoint
2nd torque limit setpoint
Speed setpoint smoothing setpoint
0 : off
1 : on
Bits 12-15
Assigned to or reserved for internal system functions
Status word 2
11005
Default value
Lower output limit
Upper output limit
Units
–
0000
FFFF
Hex
Active
after ramp-up
of 611D link
This machine data contains the high-order status bits (bits 16-31) of the cyclical status word at
the interface between SERVO and 611D.
Bits 0-2
Set of set parameters
0 to 7
Dec
Bit 3
Motor selection setpoint
0 : star
1 : delta
Bit 4
Assigned to or reserved for internal system functions
Bit 5 - SW 4
Bit 6
Bit 7
Bit 8 - SW 4
Bit 9
Motor switchover
Integrator inhibit setpoint
Pulse enable PLC setpoint
Current controller enable setpoint
Speed controller enable NC setpoint
0 : off
1 : on
7–172
©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)
Summary of Contents for SIMODRIVE 611-D
Page 2: ......