09.95
6 NC Machine Data (NC MD), NC Setting Data (NC SD)
6.8 MDs for multi-channel display
6.8
MDs for multi-channel display
MDs for screen
Multiple-channel display
20440-
20419
Default value
Lower input limit
Upper input limit
0
0
4 (as from SW 4: 6)
–
Active on
Warm restart
Reserved for customer UMS.
Multiple-channel display
20420-
20439
Default value
Lower input limit
Upper input limit
0
0
4 (as from SW 4: 6)
–
Active on
Warm restart
Reserved for system UMS.
Multiple-channel display left or top
20440
Default value
Lower input limit
Upper input limit
1
0
4 (as from SW 4: 6)
–
Active on
Warm restart
If MD 20440 is defined as 2, the basic display for channel 2 appears on the left or, in the large
actual-value display, in the upper part of the display.
Multi-channel display right or below
20441
Default value
Lower input limit
Upper input limit
2
0
4 (as from SW 4: 6)
–
Active on
Warm restart
If MD 20441 is defined as 2, the basic display for channel 2 appears on the right or, in the
large actual-value display, in the lower part of the display.
Multi-channel display reserved for the system
20442-
20449
Default value
Lower input limit
Upper input limit
Units
0
0
4 (as from SW 4: 6)
–
Active on
Power On
Reserved for the system.
©