7 Drive Machine Data (SIMODRIVE Drive MD)
04.96
7.3.2 Drive MD (data description)
Firmware date
1798
Default value
Lower output limit
Upper output limit
Units
0
0
32 767
–
Active
at once
Output of coded software version in decimal notation. The software version is output in the
following form: DDMMY, where DD = day, MM = month and Y = last digit of the year.
Example: 01.06.1993 ˆ
= 01063
dec
Firmware version
1799
Default value
Lower output limit
Upper output limit
Units
0
0
32 767
–
Active
at once
Output of present software version in decimal notation, e.g. 21000. The latter corrresponds to
version 2.10/00.
Drive machine data MSD: 2nd motor
Drive machine data, MSD for 2nd motor are listed below.
They only differ from the 1st motor by a number, not in their meaning:
•
the first number is 2.
Example
MD 1005 No. of encoder marks motor measuring system 1st motor
MD 2005 No. of encoder marks motor measuring system 2nd motor
The meaning of the MDs of the 2nd motor are identical to the MDs of the same name of the
1st motor: see description for 1st motor.
MD No. Motor 2
Title
MD No. Motor 1
2005
No. encoder marks motor measuring system
1005
2102
Motor code number (up to SW 4)
1102
2103
Motor rated current
1103
2117
Motor moment of inertia
1117
2119
Inductance of series reactor
1119
2120
P-gain current controller
1120
2121
Integral-action time current controller
1121
2125
Ramp-up time 1 for V/f operation
1125
2126
Ramp-up time 2 for V/f operation
1126
2127
Voltage when f=0 V/f operation
1127
2129
cos phi power factor
1129
2130
Motor rated power
1130
7–164
©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)
Summary of Contents for SIMODRIVE 611-D