10.94
7 Drive Machine Data (SIMODRIVE Drive MD)
7.1.2 MSD MD (data description - SW 3)
Address for stop condition
210
Default value
Lower input limit
Upper input limit
Units
0000
0000
FFFF
Hex
Active
at once
Input of address for the variable which is significant for stopping the recording (see also
MD 206).
Threshold for stop condition
211
Default value
Lower input limit
Upper input limit
Units
0000
0000
FFFF
Hex
Active
at once
Input of threshold (value) with which the contents of the variable specified in MD 210 are
compared in order to stop the recording (see also MD 206).
Address for signal 1
212
Default value
Lower input limit
Upper input limit
Units
0C00
0000
FFFF
Hex
Active
at once
Input of address of recording signal 1 (see also MD 206).
Address for signal 2
213
Default value
Lower input limit
Upper input limit
Units
0C04
0000
FFFF
Hex
Active
at once
Input of address of recording signal 2 (see also MD 206).
Start output of recording
214
Default value
Lower input limit
Upper input limit
Units
0000
0000
0001
Hex
Active
at once
Input of start for the output of the transient recorder function (see also MD 206).
The contents of the recorder memory are output via 2 DACs as soon as the above machine
data is set to 1H. The output is repeated cyclically.
Shift factor signal 1
215
Default value
Lower input limit
Upper input limit
Units
0
0
15
–
Active
at once
Input of shift factor for signal 1 (see also MD 206). The top 8 bits from a 16-bit wide memory
location are output. This machine data specifies how often the value must be shifted to the left
beforehand.
©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50
7–29
SINUMERIK 840C (IA)