12.93
7 Drive Machine Data (SIMODRIVE Drive MD)
7.1.2 MSD MD (data description - SW 3)
Control word message
247
Default value
Lower input limit
Upper input limit
Units
0000
0000
FFFF
Hex
Active
at once
By setting bits 0 to 5, it is possible to invert the function of the appropriate messages (MD 241
to MD 246). In bits 8 and 9, it is possible to choose between sign-specific or absolute-value-
based interrogation of the memory address limit values (MD 185, MD 190).
Value table:
Bit 0
Programmable message 1 inverted
0001H
Bit 1
Programmable message 2 inverted
0002H
Bit 2
Programmable message 3 inverted
0004H
Bit 3
Programmable message 4 inverted
0008H
Bit 4
Programmable message 5 inverted
0010H
Bit 5
Programmable message 6 inverted
0020H
Bits 6-7
Not assigned
Bit 8
Sign evaluation monitoring 1
0040H
Bit 9
Sign evaluation monitoring 2
0080H
Bits
10-15 Not assigned
Display of active functions 1
254
Default value
Lower output limit
Upper output limit
Units
–
–
–
Hex
Active
at once
Display of low word in drive control word.
Value table:
Bit 0
Bit 1
Bit 2-6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12-15
ZK1 reset
Parking axis
Not assigned
Ramp-function generator active
Not assigned
Ramp-function generator rapid stop
2nd torque limit
Speed setpoint smoothing
Not assigned
0: Not active
1: Active
©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50
7–37
SINUMERIK 840C (IA)
Summary of Contents for SIMODRIVE 611-D