Description:
Access_Err
Bit
Identifier
Reset
Attr. Function / Description
16dt0 ahb_apb_address
0h
rh
ahb_apb_address
26dt17 reserved
0h
27dt27 ahb_apb_select
0h
rh
ahb_apb_select
29dt28 ahb_apb_size
0h
rh
ahb_apb_size
30dt30 ahb_apb_rd_wr
0h
rh
ahb_apb_rd_wr
31dt31 err_lock
0h
rh w err_lock
Register:
Burst_Config
Address: 80Ch
Bits:
31dt0
Reset value:
0003h
Attributes: (r) (w)
Description:
Burst_Config
Bit
Identifier
Reset
Attr. Function / Description
1dt0 BurstMode_comAHB
3h
r w
At the communicative AHB slave inter-
face, an AHB RD/WR burst is
"x0": not supported (
single access
executed)
"01": supported for all burst types ex-
cept for INCR (
single access exe-
cuted)
"11": supported for all burst types
(INCR, INCR4, ... , WRAP4, ...
WRAP16)
at the SC bus.
7dt2 reserved
0h
9dt8 BurstMode_applAHB
0h
r w
At the applicative AHB slave interface, an
AHB RD/WR burst is
"x0": not supported (
single access
executed)
"01": supported for all burst types ex-
cept for INCR (
single access exe-
cuted)
"11": supported for all burst types
(INCR, INCR4, ... , WRAP4, ...
WRAP16)
at the SC bus.
31dt10 reserved
0h
Configuration rule:
If the data to be sent cyclically, which the PN-IP requests at the FSO (FrameSendOffset)
time by accessing the PerIF.IO-RAM, are to be provided in time (max. time: 1280ns,
equal to the header feed of 16 bytes), register Burst_Config = 0x0003 (default value)
must be configured.
This ensures that burst access by the PN-IP (communicative instance) is treated as such
at the IO-RAM while burst access by the applicative instances (host interface, ARM and