![Sharp AR-BC260 Service Manual Download Page 43](http://html.mh-extra.com/html/sharp/ar-bc260/ar-bc260_service-manual_365275043.webp)
AR-BC260 DESCRIPTIONS OF EACH SECTION 7 - 6
i. Paper exit roller
1) Remove the fusing unit from the machine.
2) Open the upper fusing section.
3) Remove the E-ring (A), and shift the bearing (B).
4) Remove the paper exit roller unit (C).
5) Remove the E-ring, the gear, the pin, and the bearing.
j. Lower separation pawl
1) Remove the fusing unit from the machine.
2) Open the upper fusing section.
3) Remove the paper exit roller unit.
4) Lift the separation pawl and shift it to the right and lift it from
the heat roller.
5) Remove the POD1 connector.
6) Remove the screw, and slide and remove the lower separation
pawl mounting plate.
7) Rotate the separation pawl in direction A and remove if from
the mounting plate. Remove the spring.
Note: When attaching the separation pawl, check that the separa-
tion pawl is in contact with the heat roller.
A
B
C
C
A
B
C
A