![Sharp AR-BC260 Service Manual Download Page 201](http://html.mh-extra.com/html/sharp/ar-bc260/ar-bc260_service-manual_365275201.webp)
AR-BC260 SIMULATION 9 - 63
1. Select the color to be set with the color keys (CMY).
2. The display page can be shifted with the scroll key.
(Display item)
(
D MULTI
COUNT
Print quantity
1
999
1
E PAPER
Paper feed tray selection
(MFT, CS1,CS2, CS3,
CS4, LCC)
1
6
2
(CS1)
F EXIT TRAY Paper exit tray selection
(R, S)
1
2
1 (R)
63
63
-01
Purpose
Adjustment/Setting/Operation data output, check
(display, print)
Function
(Purpose)
Used to check the result of shading correction. (The
shading correction data are displayed.)
Section
Scanner (Exposure)
Item
Operation
Operation/
Procedure
Used to display the latest shading correction result.
Data for each color can be separately checked with
the color keys.
GAIN ODD
Gain adjustment value (ODD)
1/5
GAIN EVEN
Gain adjustment value (EVEN)
OFFSET ODD
Offset value (ODD)
2/5
OFFSET EVEN
Offset value (EVEN)
SMP AVE ODD
Reference plate sampling average value
(ODD)
3/5
SMP AVE EVEN
Reference plate sampling average value
(EVEN)
TARGET VALUE Target value
4/5
BLACK LEVEL
Black output level
ERR CODE
Error code (0, 1-4, 11-14)
0: No error
1: STAGE 1, exceeded number of loops
2: STAGE 2, the target value is less
than the specified level.
3: STAGE 3, the gain set value is
negative.
4: END is not asserted.
∗
Add +1- to the error code in color
mode.
4/5
RSPF WHITE
LEVEL 1ST
White reference level of the document
feeder unit in the first scanning
5/5
RSPF WHITE
LEVEL 2nd
White reference level of the document
feeder unit in the second scanning
Display
Content
Min.
Value
Max.
Value
Default
63
-03
Purpose
Adjustment
Function
(Purpose)
Used to adjust the CCD color balance (gamma).
Section
Scanner (reading)
Item
Picture quality
Color balance
Operation/
Procedure
Set the SIT chart (UKOG-0280FCZZ) on the
document table, and press the [EXECUTE] key. The
color coefficient automatic adjustment pattern
reading is started to calculate and display the color
coefficient data.
The color coefficient data of each color can be
displayed with the color key.
63
-05
Purpose
Setting
Function
(Purpose)
Used to set the CCD color balance (gamma) default.
Section
Scanner (reading)
Item
Picture quality
Color balance
Operation/
Procedure
1. Press the [EXECUTE] key, and the [YES] and
[NO] keys become active.
2. When the [YES] key is pressed, the CCD color
balance value is set to the default.
63
-06
Purpose
Adjustment/Operation data output check (display,
print)
Function
(Purpose)
Used to check the color balance (gamma) check
patch.
Section
Image process (ICU)
Item
Picture quality
Color balance
Operation/
Procedure
1. Set the color balance check patch printed with
SIM 46-21 on the document table.
2. Press the [EXECUTE] key, and the reading is
started and the data are displayed on the display.