AR-BC260 SIMULATION 9 - 67
When the coordinates are properly set, the mark "+" on the display
turns to gray. When all the four points are pressed, the display
returns to the normal display.
The FAX-related soft SW setting is displayed on the LCD for
checking and changing.
2. Press the [EXECUTE] key. (YES/NO key display)
3. When [Yes] key is pressed, the soft SW is initialized according
to the destination code. (When [No] key is pressed, the
operation is canceled.)
The current destination code is displayed in the PRESENT
column. When [SET] key is pressed under this state, the
destination code same as that displayed in the PRESENT column
is displayed in the NEW column.
When [DEST CODE] key is pressed, the display is changed to the
message display window, indicating the country code.
15 256-gradation pattern
(Fixed gradation)
Input
process
None
❍
16 256-gradation pattern
(Certain gradation)
(Gradation specified from
external)
Input
process
None
❍
17 Whole background (half
tone)
Half tone
❍
❍
18 256-gradation pattern
(Other dither)
Half tone
None
❍
19 256-gradation pattern
(Text dither)
Half tone
None
❍
20 Half background print
LED
❍
✕
21 Half background dot print
LED
❍
✕
22 1/4 background print
LED
❍
✕
23 1/4 background dot print
LED
❍
✕
65
65
-01
Purpose
Adjustment
Function
(Purpose)
Used to adjust the touch panel (LCD display section)
detection position.
Section
Operation (Display, procedure)
Operation/
Procedure
1. Touch the four cross marks. The coordinates at
the pressed point are set.
65
-02
Purpose
Adjustment/Setting/Operation data output, check
(display, print)
Function
(Purpose)
Used to check the result of the touch panel (LCD
display) detection position adjustment. (The
coordinates are displayed.)
Section
Operation (Display, procedure)
Operation/
Procedure
When the touch panel is pressed, the AD value in
each of X and Y directions at that point and the
coordinate values are displayed in ( ) as well as the
coordinate values of each point. It is based on the
coordinates set with SIM 65-1.
No.
Content
Pattern
generating
device
Gradation
selection
Density
selection
66
66
-01
Purpose
Setting
Function
(Purpose)
Used to change/set the soft SW setting (FAX-related
items). (When the FAX is installed.)
Section
FAX
Operation/
Procedure
1. Enter the soft SW number to be selected with the
10-key.
2. Change or set the selected soft SW setting.
3. Enter [EXECUTE] key to save the setting.
66
-02
Purpose
Setting
Function
(Purpose)
Used to initialize the soft SW setting (FAX-related
items) according to the destination.
(When the FAX is installed.)
Section
FAX
Item
Data
Initializing
Operation/
Procedure
1. Enter the destination code with the 10-key, and
press [SET] key.