![Sharp AR-BC260 Service Manual Download Page 151](http://html.mh-extra.com/html/sharp/ar-bc260/ar-bc260_service-manual_365275151.webp)
AR-BC260 SIMULATION 9 - 13
C. Details
Scanning is performed at the magnification ratio set in procedure 1
is executed.
During scanning, the [EXECUTE] key is highlighted. If the
[EXECUTE] key is pressed under this state, the operation is
interrupted.
After completion of scanning, the [EXECUTE] key returns to the
normal display.
To resume scanning, start with procedure 2. To change the
magnification ratio, start with procedure 1.
Scanning is performed at the max. scanning length (432 mm). If,
however, the magnification ratio is set to a value greater than
100% in procedure 1, the scanning length is changed accordingly.
The active sensors and detectors are highlighted.
• The light source unit is at the home position. a MHPS is
highlighted.
• The light source unit is not at the home position. a MHPS is
displayed normally.
Scanning is repeatedly performed until the [EXECUTE] key or the
interruption key is pressed.
[When the RSPF is installed]
1
1
-1
Purpose
Operation test/check
Function
(Purpose)
Used to check the operations of the scanner unit and
its control circuit.
Section
Scanner (reading)
Item
Operation
Operation/
Procedure
1. Select the copy (scanning) magnification ratio
with the zoom key. The magnification ratio can
be increased or decreased with the [ZOOM] key
by the increment of 1%. The selected
magnification ratio is displayed on the
magnification ratio display.
2. Press the [EXECUTE] key.
1
-2
Purpose
Operation test/check
Function
(Purpose)
Used to check the sensors and detectors in the
scanner section and the related circuits.
Section
Scanner (reading)
Item
Operation
Operation/
Procedure
The operations of sensors and detectors in the
scanner section are displayed.
1
-5
Purpose
Operation test/check
Function
(Purpose)
Used to check the scanner (scanning) unit and its
control circuit.
Section
Scanner (reading)
Item
Operation
Operation/
Procedure
1. Select the copy (scanning) magnification ratio
with the key (touch panel). The magnification
ratio can be increased or decreased with the
[ZOOM] key by the increment of 1%.
The selected magnification ratio is displayed on
the magnification ratio display.
2. Select the scan mode (Color / B/W).
3. Press the [EXECUTE] key.
Scanning is repeated under the conditions set in
procedures 1 and 2.
During scanning, the [EXECUTE] key is
highlighted.
2
2
-2
Purpose
Operation test/check
Function
(Purpose)
Used to check the operations of the sensors and
detectors in the document feeder unit and their
related circuits.
Section
Automatic document feeder
Item
Operation
Operation/
Procedure
The operating status of the sensors and detectors in
the document feeder unit is displayed.
The active sensors and detectors are highlighted.
W0
Document set sensor
PAPER
Document transport sensor
COVER
OPEN
Unit (OC cover) open/close sensor
PO
Paper exit sensor
COVER
Paper feed cover open/close sensor
L1
Document length sensor 1
L2
Document length sensor 2
W1
Document width sensor (small)
W2
Document width sensor (middle)
W3
Document width sensor (large)