AR-BC260 TROUBLESHOOTING 11 - 18
Main
code
Sub
code
Title
Half-tone process limit error
F2
90
Display
Lamp/Message
Phenomenon Detail
The difference between the
correction value after
execution of half-tone
process control and the
previous correction value
exceeds the specified max.
value of each color.
<The error is recorded in
the trouble history, but F2
trouble is not indicated on
the display and the previous
correction value is
remained.>
Section
—
Common
Check
Use SIM 44-2 to adjust the
process control sensor
gain.
Case 1
Cause
When "Error" occurs in the
gain adjustment of SIM 44-
2:
1. Disconnection of the
harness between the
PCU PWB and the
image density sensor.
2. Image density sensor
dirt/trouble.
Check &
Remedy
1. Check connection of the
harness between the
PCU PWB and the
image density sensor.
2. Clean/replace the image
density sensor.
Case 2
Cause
When SIM 44-2 gain
adjustment is completed:
Insufficient cleaning of the
transfer belt, calibration
plate solenoid operation
trouble
Check &
Remedy
Check the drum surface
and the belt surface.
Main
code
Sub
code
Title
Cassette 1 lift up trouble
F3
12
Display
Lamp/Message
Phenomenon Detail
LUD1 does not turn on
within the specified time.
Section
—
Case 1
Cause
LUD1 sensor trouble,
disconnection of harness
among the PCU PWB, the
lift-up unit, and the paper
feed unit.
Check &
Remedy
Check LUD1, its harness,
and the connector.
Case 2
Cause
Cassette 1 lift-up motor
trouble
Check &
Remedy
Check the lift-up unit.
Main
code
Sub
code
Title
ICU-FAX communication trouble
(ICU detection)
F6
00
Display
Lamp/Message
Phenomenon Detail
Communication
establishment error,
framing, parity, protocol
error
Section
FAX
Case 1
Cause
Slave unit PWB connector
connection trouble. Slave
unit PWB-ICU PWB
harness trouble
Check &
Remedy
Check connection between
the slave unit PWB and the
ICU PWB, and check the
harness.
Case 2
Cause
Broken pin of the mother
board connector of the
slave unit PWB
Check &
Remedy
Check the connector of the
slave unit PWB.
Case 3
Cause
Slave unit ROM trouble/ No
ROM/ Improper insertion of
ROM/ ROM pin breakage
Check &
Remedy
Check grounding of the
main unit. Check the ROM
of the slave unit PWB.
Main
code
Sub
code
Title
FAX expansion flash memory
abnormality (ICU detection)
F6
01
Display
Lamp/Message
Phenomenon Detail
An expansion flash memory
with SRAM backup data in it
is installed.
Section
FAX
Case 1
Cause
SRAM backup data are
detected in the expansion
flash memory. The
simulation function (SIM 66-
19) is provided to save
SRAM backup data into an
expansion flash memory.
This trouble occurs when an
expansion flash memory to
which SRAM backup data
are saved with the above
function is installed.
Check &
Remedy
Use SIM 66-20 to restore
the backup data to the
SRAM, and use SIM 66-10
to clear the expansion flash
memory. If the data are
unnecessary, simply clear
the expansion memory with
SIM 66-10.