AR-BC260 SIMULATION 9 - 70
(Sendable voice message)
(Items to be set)
(Items to be set)
(Adjustable items)
66
-12
Purpose
Operation test/check
Function
(Purpose)
Used to select a pattern and send it to the line and
the speaker at 300bps. (Level: soft SW setting)
(When the FAX is installed.)
Section
FAX
Item
Operation
Operation/
Procedure
1. Select the pattern to be sent.
2. Press the [EXECUTE] key.
NO SIGNAL
No signal (CML ON)
00000
Repetition of "00000"
11111
Repetition of "11111"
10101
Repetition of "10101"
11110
Repetition of "11110"
00001
Repetition of "00001"
66
-13
Purpose
Setting
Function
(Purpose)
Used to register a dial number for test used in SIM
66-14/15/16. (When the FAX is installed.)
Section
FAX
Item
Data
Registration
Operation/
Procedure
If a dial number is already registered, it is displayed
on "PRESENT: ."
1. Enter a dial number with the 10-key (displayed
on NEW:) and press [SET] key. The registered
number is displayed on "PRESENT:."
66
-14
Purpose
Adjustment
Function
(Purpose)
Used to adjust and check the make time of dial pulse
(10pps). (When the FAX is installed.)
Section
FAX
Item
Operation
Operation/
Procedure
1. Enter the make time to be set with the 10-key.
2. Press [OK] key to set.
3. Press [EXECUTE] key to send the pulse (dial set
with SIM 66-13).
Item
Set range
Default
A
Make time
0 – 15
11 (Europe)
6 (Australia, New Zealand)
66
-15
Purpose
Adjustment
Function
(Purpose)
Used to adjust and check the make time of the dial
pulse (20pps). (When the FAX is installed.)
Section
FAX
Item
Operation
Operation/
Procedure
1. Enter the make time to be set with the 10-key.
2. Press [OK] key to set.
3. Press [EXECUTE] key to send the pulse (dial set
with SIM 66-13).
Item
Set range
Default
A
Make time
0 – 15
8
66
-16
Purpose
Adjustment
Function
(Purpose)
Used to adjust and check the send level of DTFM
signal. (When the FAX is installed.)
Section
FAX
Item
Operation
Operation/
Procedure
1. Select an item to be adjusted with the scroll key.
2. Enter the set value with the 10-key.
3. Press [OK] key to set.
4. Press [EXECUTE] key to send pulses (dial set
with SIM 66-13) from the line at each setting of
the high group and the low group of the send
level.
Item
Set range
Default
A
Level (db)
0 – 15
5
B
Difference between the high and the
low groups
0 – 15
1