AR-BC260 SIMULATION 9 - 39
2. Press the [EXECUTE] key. The [EXECUTE] key is highlighted
then it returns to the normal display. The manual paper feed
guide max. width position detection level is recognized.
3. Set the manual paper feed guide to A4 (11 x 8.5") size.
4. Press the [EXECUTE] key. The key is highlighted then it
returns to the normal display. The manual paper feed guide A4
(11 x 8.5") detection level is recognized.
5. Set the manual paper feed guide to A4R (11 x 8.5R) size.
6. Press the [EXECUTE] key. The key is highlighted then it
returns to the normal display. The manual paper feed guide A4
R (11 x 8.5"R) detection level is recognized.
7. Set the manual paper feed guide to the minimum size.
8. Press the [EXECUTE] key. The key is highlighted then it
returns to the normal display. The manual paper feed guide
minimum size detection level is recognized.
If the above operation is not performed properly, the ERROR
display is highlighted. If performed properly, the above data is
stored and the COMPLETE is highlighted.
∗
This simulation is not normally used. Adjustment is made with
SIM 40-02.
(Set range)
(Sensors to be detected)
2. Set an A3 paper (11" x 17") and press the [EXECUTE] key.
The sensor level setting with document is performed.
3. The message of completion of the adjustment is displayed.
40
-2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the manual feed tray paper width
detector detection level.
Section
Paper feed
Item
Operation
Operation/
Procedure
1. Set the manual paper feed guide to the
maximum size.
40
-7
Purpose
Setting
Function
(Purpose)
Used to enter the adjustment value of the manual
paper feed tray paper width detector detection level.
(Setting)
Section
Paper feed
Item
Specifications
Operation/
Procedure
1. Select the item (setting) to be entered with the
scroll key.
2. Enter the adjustment value with the 10-key pad.
3. Press the [OK] key.
Item
Set range
Default
A
MAX POSITION
0 – 255
241
B
P1 POSITION
0 – 255
231
C
P2 POSITION
0 – 255
140
D
MIN POSITION
0 – 255
19
41
41
-1
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the document size
sensor and the related circuit. (The operation of the
document size sensor can be monitored with the
LCD display.) Sensor ON/OFF check
Section
Others
Item
Operation
Operation/
Procedure
The active sensors and detectors are highlighted.
OCSW
OC cover open/close
detection
Open: Highlighted,
Close: Normal
PD1
Document sensor 1
No document (not detected):
Normal
Document loaded (detected):
Highlighted
PD2
Document sensor 2
PD3
Document sensor 3
PD4
Document sensor 4
PD5
Document sensor 5
PD6
Document sensor 6
PD7
Document sensor 7
41
-2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the document size sensor detection
level.
Section
Others
Item
Operation
Operation/
Procedure
1. Open the document table, and press the
[EXECUTE] key without document on the
document table. The sensor level setting with no
document on the table is performed.