![Sharp AR-BC260 Service Manual Download Page 178](http://html.mh-extra.com/html/sharp/ar-bc260/ar-bc260_service-manual_365275178.webp)
AR-BC260 SIMULATION 9 - 40
∗
The value in [ ] shown at the right of each sensor name is the
threshold value.
PD1 – PD7 light receiving (A/D value) and threshold value (A/D
value) range is 1 – 255. The default of the threshold value is 128.
2. Enter the set value with the 10-key.
3. Press the [OK] key to set the fusing temperature set in
procedure 2.
(Display items)
(Display items)
41
-3
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the document size
sensor and the related circuit. (The document size
sensor output level can be monitored with the LCD
display.) Current sensor (A/D) value
Section
Others
Item
Operation
Operation/
Procedure
The detection output level of each sensor (PD1 ~
PD7) is displayed in real time.
43
43
-1
Purpose
Setting
Function
(Purpose)
Used to set the fusing temperature in each operation
mode.
Section
Fixing (Fusing)
Item
Operation
Operation/
Procedure
1. Select the kind of lamps and the operation mode
with the scroll key.
Display
Content
Set
range
Default
100v
Series
120v
Series
200v
Series
China
only
A
TH1 ready standby
70 – 230
150
150
150
150
B
TH2 ready standby
30 – 200
135
135
135
135
C
TH1 BW normal paper
duplex mode
70 – 230
160
160
160
160
D
TH2 BW normal paper
duplex mode
30 – 200
145
145
145
145
E
TH1 color normal paper
duplex mode
70 – 230
145
145
145
145
F
TH2 color normal paper
duplex mode
30 – 200
135
135
135
135
G
Fusing motor forward
rotation start TH12
temperature
30 – 200
135
135
135
135
H
Fusing motor forward
rotation end TH2
temperature
30 – 200
135
135
135
135
I
Warm-up completion
time
90 – 255
90
90
90
90
J
TH1 heavy paper
70 – 230
170
170
170
170
K
TH2 heavy paper
30 – 200
135
135
135
135
L
TH1 heavy paper 2
70 – 230
175
175
175
175
M
TH2 heavy paper 2
30 – 200
145
145
145
145
N
TH1 OHP1
70 – 230
170
170
170
170
O
TH2 OHP1
30 – 200
155
155
155
155
P
TH1 OHP2
70 – 230
170
170
170
170
Q
TH2 OHP2
30 – 200
155
155
155
155
R
TH1 envelope
70 – 230
180
180
180
180
S
TH2 envelope
30 – 200
145
145
145
145
T
TH1 preheating
30 – 200
138
138
138
138
U
Reset from TH1
preheating
30 – 200
160
160
160
160
43
-4
Purpose
Setting
Function
(Purpose)
Used to set the fusing temperature for each paper.
Section
Fixing (Fusing)
Item
Operation
Operation/
Procedure
1. Select the paper kind and the operation mode
with the scroll key.
2. Enter the set value with the 10-key.
3. Press the [OK] key to set the fusing temperature
set in procedure 2.
Display
Content
Set
range
Default
100v
Series
120v
Series
200v
Series
China
only
A
TH1 BW normal paper
duplex mode
70 – 230
155
155
155
155
B
TH2 BW normal paper
duplex mode
30 – 200
100
100
100
100
C
Applicable number of
sheets in BW normal
paper duplex mode
0 – 60
0
0
0
0
D
TH1 color normal paper
duplex mode
70 – 230
150
150
150
150
E
TH2 color normal paper
duplex mode
30 – 200
100
100
100
100
F
Applicable number of
sheets in color normal
paper duplex mode
0 – 60
0
0
0
0
G
TH1 BW heavy paper
duplex mode
70 – 230
165
165
165
165
H
TH2 BW heavy paper
duplex mode
30 – 200
100
100
100
100
E
Applicable number of
sheets in BW heavy
paper duplex mode
0 – 60
0
0
0
0
F
TH1 color heavy paper
duplex mode
70 – 230
165
165
165
165
G
TH2 color heavy paper
duplex mode
30 – 200
100
100
100
100
H
Applicable number of
sheets of color heavy
paper duplex mode
0 – 60
0
0
0
0
I
LL environment
temperature set value
0 – 99
18
18
18
18
J
HH environment
temperature set value
0 – 99
30
30
30
30