Main
Sub
Item
Content
Adjustment
code
code
range
24
05
Clears staple
counter.
[Content] The staple counter is cleared and then staple counter is displayed.
(a)
Operation/display
[1]:
The simulation is executed and the screen changes to the RADF counter
screen.
[2]:
The simulation is stopped and the screen returns to the sub code input
screen.
If any key other than [1]or [2] is pressed, the error buzzer sounds.
[PAUSE]:
The execution of the simulation is stopped and the screen returns to the
sub code input screen.
[CA]:
The execution of the simulation is stopped and the simulation is terminated.
07
Clears drum
adjustment
counter.
SIMULATION NO.24- 7
DRUM ADJUSTMENT TIME
WOULD YOU MIND IF CLEARING EXECUTE?
1. EXECUTE 2. CANCEL
SELECT WITH TEN KEY
• [1] key
SIMULATION NO.24- 7
DRUM ADJUSTMENT TIME
COMPLETED CLEARING
DRUM ADJUSTMENT TIME DISPLAY
DRUM ADJUSTMENT: 000,000 [S]
[PAUSE]KEY: END DISPLAY
[Content] The drum adjustment counter is cleared and then the drum adjustment counter is
displayed.
(a)
Operation/display
[1]:
The simulation is executed and the screen changes to the drum adjustment
counter screen.
[2]:
The simulation is stopped and the screen returns to the sub code input
screen.
If any key other than [1] or [2] is pressed, the error buzzer sounds.
[PAUSE]:
The execution of the simulation is stopped and the screen returns to the
sub code input screen.
[CA]:
The execution of the simulation is stopped and the simulation is terminated.
9 – 42