Main
Sub
Item
Content
Adjustment
code
code
range
27
04
Sets start/end
of service.
[Content] The start/end of service in the PPC communication system can be set. Select
either the start service or the end of service and the PPC will send the correspond-
ing command to the PC/Modem. If the PC/Modem receives the command, the
message indicating that setting is complete appears.
(a)
Operation/display
[1]:
Sends the service start command.
[2]:
Sends the service end command.
If any key other than [1] or [2] is pressed, the error buzzer sounds.
[PAUSE]:
No setting is made and the sub code input screen is displayed.
[CA]:
The execution of the simulation is stopped and the simulation is terminated.
05
Sets tag
number.
SIMULATION NO.27- 5
PPC TAG NUMBER SETTING
CURRENT TAG NUMBER
XXXXXXXXXX
CHANGE THIS TAG NUMBER ?
1. YES 2. NO
SELECT WITH TEN KEY
• [1] key
SIMULATION NO.27- 5
PPC TAG NUMBER SETTING
CURRENT TAG NUMBER
XXXXXXXXXX
NEW TAG NUMBER
__________
INPUT SETUP VALUE AND PRESS PRINT SW
SIMULATION NO.27- 5
PPC TAG NUMBER SETTING
CURRENT TAG NUMBER
XXXXXXXXXX
[PAUSE]KEY:END DISPLAY
[Content] The PPC tag number (grade-up number) can be set. The screen displays the
current setting of the tag number. If you want to change the setting, press the [1]
key to display the tag number input screen. Enter a new tag number. Press the
[PRINT] key to register the new tag number.
(a)
Operation/display
[PRINT]:
If the entered value is valid, the current setting is updated and the screen
changes to the next one.
If the entered value is not valid, the input field is cleared and the error
buzzer sounds.
[0-9]:
Enters new settings.
[C]:
Clears the input field.
[PAUSE]:
No setting is made and the sub code input screen is displayed.
[CA]:
The execution of the simulation is stopped and the simulation is terminated.
9 – 55