Main
Sub
Item
Content
Adjustment
code
code
range
50
Adjusts the
leading edge
position of the
copy.
SIMULATION NO.50- _
1, 2, 5.ADJUST THE COPY LEAD EDGE
IMAGE LOSS AND VOID AREAS
3.SET THE COPY LEAD EDGE IMAGE
LOSS AND VOID AREAS
10.PRINT OFCENTER ADJUSTMENT
12.ORIGINAL OFCENTER ADJUSTMENT
14.PRINT OFCENTER SETTING
15.ORIGINAL OFCENTER SETTING
INPUT_SUB NO. AND PRESS PRINT SWITCH
01
Adjusts the
leading edge
position of the
image.
RRC-A: 0-99
RRC-B: 0-99
DEN-B: 0-99
[Content] The leading edge position of the image can be adjusted.
If the [PRINT] key is pressed after entering a sub code, the copier exits the
simulation mode and starts warming up. After warming up, the copier becomes the
copy ready state. At this time, the leading edge position setting of the image is
displayed on the multiple display. However, if the warming up action is finished by
another sub code, the shading/process control is omitted.
The setting can be changed with the numeric keypad. By pressing the [PRINT]
key, a copy can be made. You can move from one item to another with the [
→
]
key.
The selection between cassette feed and manual feed can be made with the
[CASSETTE SELECTION] key. If the [PRINT] key is pressed without entering any
setting, a copy can be made. However, the multiple copy function is not available.
Adjustment range
Leading edge adjustment value
RRC-A:
0
∼
99
Leading edge adjustment value
RRC-B:
0
∼
99
With RRC_A=60, RRC_B=00, make a 400% copy. Call the distance from the
leading edge of the image to the 5-mm position on the scale as L1 [mm] and
the distance from the leading edge of the paper to the leading edge of the
image as L2 [mm]. The adjustment values of RRC_A and RRC_B can be
obtained by the following equation.
RRC_A= Previous s (L1
×
10 – 120)
×
100/copy ratio
RRC_B= L2
×
10 – 20
Adjustment range
Trailing edge void
DEN-B:
0
∼
99
The leading/trailing edge void increases 0.1 mm for every “+1” in adjustment value.
The leading/trailing edge void decreases 0.1 mm for every “–1” in adjustment value.
• [CASSETTE SELECTION] key
WARMING UP.
PLEASE WAIT.
60
TRAY ADJUSTMENT
RRC_A [XX]
60
RRC_B [XX]
DEN_B [XX]
0~99
MFT ADJUSTMENT
60
RRC_B [XX]
DEN_B [XX]
0~99
9 – 69