Main
Sub
Item
Content
Adjustment
code
code
range
42
Clears
developer
counter.
SIMULATION NO.42
DEVELOPER COUNTER CLEAR
WOULD YOU MIND IF CLEARING EXECUTE?
1. EXECUTE 2. CANCEL
SELECT WITH TEN KEY
• [1] key
SIMULATION NO.42
DEVELOPER COUNTER CLEAR
COMPLETED CLEARING
DEVELOPER COUNTER DISPLAY
DEVELOPER:000,000
[PAUSE]KEY:END DISPLAY
[Content] The developer counter is cleared and then the developer counter is displayed.
(a)
Operation/display
[1]:
The simulation is executed and the screen changes to the developer
counter screen.
[2]:
The execution of the simulation is stopped and the screen changes to the
main code input screen.
If any key other than [1] or [2] is pressed, the error buzzer sounds.
[PAUSE]:
The execution of the simulation is stopped and the screen changes to the
sub code input screen.
[CA]:
The execution of the simulation is stopped and the simulation is terminated.
43
Sets fusing
temperature.
SIMULATION NO.43- _
1.FUSER TEMPERATURE SETUP
(NORMAL MODE)
2.FUSER TEMPERATURE SETUP
(ECONOMY MODE)
INPUT SUB NO. AND PRESS PRINT SWITCH
01
Sets fusing
temperature
(normal mode).
160-205
SIMULATION NO.43- 1
FUSER TEMPERATURE SETUP (NORMAL MODE)
[XXX]:_ °C
160°C , 185°C
165°C , 190°C
170°C , 195°C
175°C , 200°C
180°C , 205°C
INPUT SETUP VALUE AND PRESS PRINT SW
9 – 60