Main
Sub
Item
Content
Adjustment
code
code
range
08
02
Sets and
checks
charging/grid
output.
200-900
200-900
200-900
200-900
200-900
200-900
• Charging/grid bias outputting in progress
SIMULATION NO. 8- 2
MAIN CORONA OUTPUT
AUTO EXPOSURE MODE
MAIN CORONA [XXX]
[PAUSE]KEY: END OUTPUT CHECK
SIMULATION NO. 8- 2
MAIN CORONA OUTPUT
MANUAL EXPOSURE MODE
SIMULATION NO. 8- 2
MAIN CORONA OUTPUT
PHOTOGRAPHIC MODE
SIMULATION NO. 8- 2
MAIN CORONA OUTPUT
SOFT PHOTOGRAPHIC MODE
SIMULATION NO. 8- 2
MAIN CORONA OUTPUT
TONER SAVE MODE
SIMULATION NO. 8- 2
MAIN CORONA OUTPUT
PRINTER MODE
[Content] If the [PRINT] key is pressed after entering a sub code, the copier enter the
execution wait mode and the ready lamp comes on. The current grid bias voltage
setting is displayed. The setting can be changed with the numeric keypad and
updated by pressing the [PRINT] key. (The cursor indicates the same grid voltage
item.)
If the [PRINT] key is pressed without entering any new setting, the ready lamp
goes out and both the charging charger voltage and the grid bias voltage are
output at the current settings for 30 seconds. After outputting, the screen returns
to the execution wait mode screen.
Setting
Grid bias
200:
–200 V
900:
–900 V
<Note> The set value does not coincide with the output voltage.
9 – 26