Main
Sub
Item
Content
Adjustment
code
code
range
61
Laser output
check.
SIMULATION No.61- _
1.LASER SCANNER UNIT ACTIVATION
2.LASER OUTPUT POWER SETTING
INPUT SUB NO. AND PRESS PRINT SWITCH
01
Check LSU
activation.
SIMULATION No.61- 1
LASER SCANNER UNIT ACTIVATION
POLYGON MOTOR : READY
BEAM DETECT SENSOR: HSYNC
[PAUSE]KEY:END ACTIVATION
[Content] The LSU polygon motor is rotated and the laser lights and stays for 30 seconds. At
that time, the polygon motor lock detection and laser synchronizing signal are
monitored. After the operations, the screen returns to the sub code input screen.
(a)
Operation/display
[PAUSE]:
The execution of the simulation is stopped and the sub code input screen is
displayed.
[CA]:
The execution of the simulation is stopped and the simulation is terminated.
02
Sets laser
power.
0-15
SIMULATION No.61- 2
LASER OUTPUT POWER SETTINGON
AUTO EXPOSURE MODE[XX]: XX
MANUAL EXPOSURE MODE[XX]: XX
PHOTOGRAPHIC MODE[XX]: XX
SOFT PHOTOGRAPHIC MODE[XX]: XX
TONER SAVE MODE[XX]: XX
PRINTER MODE[XX]: XX
(0~15)
[|]KEY:MOVE PRINT SW:EXECUTE
[Content] The LSU laser power output can be set. The current setting is displayed and a
new setting can be entered.
Adjustment range
Laser power output value:
0
∼
15
Setting
Light/output ratio
0:
100.0%
3:
87.5%
6:
75.0%
9:
62.5%
12:
50.0%
15:
37.5%
(a)
Operation/display
[PRINT]:
If the entered value is valid, the current setting is updated and the input
field changes to the next one. If the entered value is not valid, the input field
is cleared and the error buzzer sounds.
If any value is not entered, no setting is made and the screen changes to
the sub code input screen.
[0-9]:
Enters new settings.
[C]:
Clears the input field.
[PAUSE]:
No setting is made and the sub code input screen is displayed.
[CA]:
The execution of the simulation is stopped and the simulation is terminated.
9 – 82