53
06
Adjusts RADF
repulsion
sensor.
0-127
SIMULATION No.53- 6
RADF REPULSION SENSOR ADJUSTMENT
PRINT SWITCH:EXECUTE SIMULATION
• Eject/inversion sensor adjustment completed
SIMULATION No.53- 6
RADF REPULSION SENSOR ADJUSTMENT HAS
COMPLETED
ADJUSTMENT VALUE:XXX
[PAUSE]KEY:END DISPLAY
[Content] The RADF repulsion sensor can be adjusted.
If the [PRINT] key is pressed to execute the simulation, the RADF repulsion
sensor reference value is adjusted and the adjusted value is displayed.
Adjustment range
RADF: 0
∼
127
(a)
Operation/display
[PRINT]:
The adjustment simulation is executed.
[PAUSE]:
The execution of the simulation is stopped and the sub code input screen is
displayed.
[CA]:
The execution of the simulation is stopped and the simulation is terminated.
07
Adjusts RADF
timing sensor.
0-127
SIMULATION No.53- 7
RADF TIMING SENSOR ADJUSTMENT
PRINT SWITCH:EXECUTE SIMULATION
• Timing sensor adjustment completed
SIMULATION No.53- 7
TIMING SENSOR ADJUSTMENT HAS COMPLETED
ADJUSTMENT VALUE:XXX
[PAUSE]KEY:END DISPLAY
[Content] The RADF timing sensor can be adjusted.
If the [PRINT] key is pressed to execute the simulation, the RADF timing sensor
reference value is adjusted and the adjusted value is displayed.
Adjustment range
RADF: 0
∼
127
(a)
Operation/display
[PRINT]:
The adjustment simulation is executed.
[PAUSE]:
The execution of the simulation is stopped and the sub code input screen is
displayed.
[CA]:
The execution of the simulation is stopped and the simulation is terminated.
9 – 81