Main
Sub
Item
Content
Adjustment
code
code
range
46
01
Adjusts
exposure level
(copy).
To clear the exposure adjustment mode:
1. Turn ON the [CA] key, or
2. Turn ON/OFF the main switch (on the left-side of the copier), or
3. Enter the simulation mode and press the [CA] key to exit the simulation mode.
02
Inputs exposure
level adjustment
value (setting in
each copy
mode).
AE: 0-200
ME: 0-200
SIMULATION NO.46- 2
EXPOSURE LEVEL SETTING (EACH MODE)
COPY (MANUAL MODE) 0~200
N_1 [XXX]:XXX N_3.5[XXX]:XXX
N_1.5[XXX]:XXX N_4 [XXX]:XXX
N_2 [XXX]:XXX N_4.5[XXX]:XXX
N_2.5[XXX]:XXX N_5 [XXX]:XXX
N_3 [XXX]:XXX
COPY (AUTO MODE) AE_3 [XXX]:XXX 0~200
[|]KEY:MOVE PRINT SW:EXECUTE
[DENSITY]KEY:CHANGE DENSITY MODE
[DENSITY] key
SIMULATION NO.46- 2
EXPOSURE LEVEL SETTING (EACH MODE)
COPY (PHOTO MODE) 0~200
P_1 [XXX]:XXX P_3.5[XXX]:XXX
P_1.5[XXX]:XXX P_4 [XXX]:XXX
P_2 [XXX]:XXX P_4.5[XXX]:XXX
P_2.5[XXX]:XXX P_5 [XXX]:XXX
P_3 [XXX]:XXX
[|]KEY:MOVE PRINT SW:EXECUTE
[DENSITY]KEY:CHANGE DENSITY MODE
PH: 0-200
[DENSITY] key
SIMULATION NO.46- 2
EXPOSURE LEVEL SETTING (EACH MODE)
COPY (SOFT_PHOTO MODE) 0~200
SFTP_1 [XXX]:XXX SFTP_3.5[XXX]:XXX
SFTP_1.5[XXX]:XXX SFTP_4 [XXX]:XXX
SFTP_2 [XXX]:XXX SFTP_4.5[XXX]:XXX
SFTP_2.5[XXX]:XXX SFTP_5 [XXX]:XXX
SFTP_3 [XXX]:XXX
[|]KEY:MOVE PRINT SW:EXECUTE
[DENSITY]KEY:CHANGE DENSITY MODE
SPH: 0-200
[Content] The exposure level adjustment value in each copy mode can be set. The current
setting is displayed and a new setting can be entered.
(a)
Operation/display
[PRINT]:
If the entered value is valid, the current setting is updated and the next
input field is displayed. If the entered value is not valid, the input field is
cleared and the error buzzer sounds.
If any value is not entered, the setting is not updated and the screen
changes to the sub code input screen.
[0-9]:
Enters new settings.
[
→
]:
Moves the input field.
[C]:
Clears the input field.
[DENSITY]: Switches over copy density modes
[PAUSE]:
No setting is made and the sub code input screen is displayed.
[CA]:
The execution of the simulation is stopped and the simulation is terminated.
9 – 66