Main
Sub
Item
Content
Adjustment
code
code
range
21
Maintenance
cycle setting.
SIMULATION NO.21- _
1.MAINTENANCE CYCLE SETTING
INPUT SUB NO. AND PRESS PRINT SWITCH
01
Sets
maintenance
cycle.
0-5
SIMULATION NO.21- 1
MAINTENANCE CYCLE SETTING [X] :_
0. 80,000 SHEETS
1. 40,000 SHEETS
2. 5,000 SHEETS
3. 10,000 SHEETS
4. 20,000 SHEETS
5. FREE
INPUT SETUP VALUE AND PRESS PRINT SW
[Content] The current maintenance cycle setting is displayed and a new setting is entered.
After the execution of the simulation, the screen returns to the sub code input
screen.
(a)
Operation/display
[PRINT]:
If the entered value is valid, the current setting in brackets is updated. If the
entered value is not valid, the entered value is cleared and the error buzzer
sounds. If the [PRINT] key is pressed without entering any new setting, the
current setting is not updated.
[0-9]:
Enters new settings
[C]:
Clears the entered value.
[PAUSE]:
The execution of the simulation is stopped and the screen returns to the
sub code input screen.
[CA]:
The execution of the simulation is stopped and the simulation is terminated.
22
Displays
counters.
SIMULATION NO.22- _
COUNTER AND CODE DISPLAY
1.MAINTE COUNTER 10.STAPLE COUNTER
2.MAINTE PRESET 12.DRUM ADJUST TIME
4.MISFEED COUNTER 13.KEY OPE CODE
5.TOTAL COUNTER 14.ROM VERSION
6.DEV. COUNTER 15.TROUBLE MEMORY
7.DEV. PRESET 16.COPY COUNTER
8.RADF COUNTER 17.PDA/ZR COUNTER
9.TRAY/ADU COUNTER 20.PRINTER COUNTER
INPUT SUB NO. AND PRESS PRINT SWITCH
9 – 31