Main
Sub
Item
Content
Adjustment
code
code
range
26
01
Optional setting.
0-15
SIMULATION NO.26- 1
OPTION UNIT SETUP [XX] :_
5.RADF + DESK
15.RADF + DESK + SORTER
INPUT SETUP VALUE AND PRESS PRINT SW
[Content] Optional setting can be made. The current setting is displayed and a new setting
can be entered.
Default value: 5
Note:
Turning on the power with no desk connected causes the trouble "U6-00,"
thereby disabling the machine operation.
(a)
Operation/display
[PRINT]:
If the entered value is valid, the current setting is updated and the sub code
input screen is displayed. If the entered value is not valid, the input field is
cleared and the error buzzer sounds. If any value is not entered, the setting
remains unchanged and the sub code input screen is displayed.
[0-9]:
Enters new settings
[C]:
Clears the input field.
[PAUSE]:
No setting is made and the sub code input screen is displayed.
[CA]:
The execution of the simulation is stopped and the simulation is terminated.
02
Sets foolscap
paper.
1-2
SIMULATION NO.26- 2
FOOLSACP SETUP [X] :_
1. 8 1/2
×
1 4
2. 8 1/2
×
1 3
INPUT SETUP VALUE AND PRESS_PRINT SW
[Content] The detection size of the foolscap paper can be set for 8 1/2 x 14 inch or 8 1/2 x
13 inch. The current setting is displayed and a new setting can be entered.
(a)
Operation/display
[PRINT]:
If the entered value is valid, the current setting is updated and the sub code
input screen is displayed. If the entered value is not valid, the input field is
cleared and the error buzzer sounds. If any value is not entered, the setting
remains unchanged and the sub code input screen is displayed.
[1-2]:
Enters new settings
[C]:
Clears the input field.
[PAUSE]:
No setting is made and the sub code input screen is displayed.
[CA]:
The execution of the simulation is stopped and the simulation is terminated.
9 – 47