Register Name
M1
Address
M2
Address
Read/
Write
Notes
that there is span-gas in the cell which may
give incorrect measurements
If this flag is set, it can be cleared by doing a
complete auto val with the cell being
successfully purged at the end.
Debug message
50007
50087
R
Reading this address causes some debug
information to be printed to the system log.
This is for Servomex use only.
Auto Val supported for
this measurement
50008
50088
R
0 = Auto val not supported
1 = Auto val supported
Correct password
received
50009
50089
R
0 = password not received
1 = password received - auto val is now
enabled
Requested zero-gas
state
50024
50104
R
The analyzer uses this address to tell the HMI
when to turn the zero-gas on or off. The HMI
should monitor this register and set the zero-
gas state accordingly
0 = HMI should turn off zero-gas
1 = HMI should turn on zero-gas
Requested span-gas
state
50025
50105
R
The analyzer uses this address to tell the HMI
when to turn the span-gas on or off. The HMI
should monitor this register and set the span-
gas state accordingly
0 = HMI should turn off span-gas
1 = HMI should turn on span-gas
Set Stability Time
50026
50106
R/W
The measurement must be within the stability
criteria for this length of time before taking a
zero or span measurement. Unit = sec
Set Flush Time
50027
50107
R/W
Allow the zero or span-gas to flush through for
this length of time before looking for a stable
zero or span measurement. Unit = sec
Set Timeout
50028
50108
R/W
If the measurement is not stable after this
length of time, carry on with auto validation
regardless. Unit = sec
set validation pressure
50041
50121
R/W
set validation pressure for auto val on
measurement 1
set validation
temperature
50043
50123
R/W
set validation temperature for auto val on
measurement 1
set validation gas
concentration
50045
50125
R/W
set validation gas concentration for auto val on
measurement 1
set validation gas
tolerance
50047
50127
R/W
set validation gas tolerance for auto val on
measurement 1
set validation pass level
50049
50129
R/W
set validation pass level for auto val on
measurement 1
set validation cell
length
50051
50131
R/W
set validation cell length for auto val on
measurement 1
set validation
concentration standard
deviation tolerance
50053
50133
R/W
set validation concentration standard deviation
tolerance for auto val on measurement 1
set validation
transmission standard
deviation tolerance
50055
50135
R/W
set validation transmission standard deviation
tolerance for auto val on measurement 1
set low signal threshold
50057
50137
R/W
set low signal threshold for auto val on
measurement 1
Summary of Contents for 07931001B
Page 2: ...Servomex Group Limited 2020 This page intentionally blank...
Page 4: ...Servomex Group Limited 2020 This page intentionally blank...
Page 12: ...viii Servomex Group Limited 2020 07931001B revision 6 This page intentionally blank...
Page 14: ...x Servomex Group Limited 2020 07931001B revision 6 This page intentionally blank...