Troubleshooting the power unit (trouble code not detected)
Troubleshooting when a trouble code is not available consists of the following 4 items.
Symptom 1: Specific trouble conditions
Symptom 2: Trouble conditions of an area or individual part
Cause 1: The content considered as the trouble factors of symptom 2.
Cause 2: The content considered as the trouble causes of cause 1 (described if necessary).
Symptom 1: Engine does not crank
Symptom 2
Cause 1
Cause 2
Checking step
Refer
to
page
Starter motor
does not
operate
Discharged battery
—
Check the battery.
3-15
Loose connection of
battery terminal
—
Check the battery ter-
minal.
3-15
Short, open, or loose
connection in starter
motor circuit
—
Check the wiring har-
ness continuity.
*1
Starter relay malfunc-
tion
—
Check the starter relay.
8-32
Blown fuse
—
Check the fuse.
8-5
Starter motor malfunc-
tion
—
Disassemble and check
the starter motor.
8-34
Engine start switch
malfunction
—
Check the engine start
switch.
8-20
Gear shift not in the
neutral position
—
Shift the remote control
lever to the neutral
position.
1-42
Starter motor
operates, but
the engine does
not crank
Stuck piston
—
Disassemble and check
the power unit.
5-1
Piston lock due to water
or oil in the combustion
chamber
Salt buildup on the
drive shaft and bushing
—
Disassemble and check
the upper case.
7-5
Starter motor malfunc-
tion
—
Disassemble and check
the starter motor.
8-34
*1: See the wiring diagram.
Summary of Contents for Blue Whale 250 EFI
Page 1: ...Blue Whale 250 SERVICE MANUAL...
Page 97: ...6P23H11 4 14 1 2 3 4 5 6 7 8 9 1 2 3 S6P24380 2 3 Intake manifold...
Page 111: ...6P23H11 4 28 1 2 3 4 5 6 7 8 9 MEMO Fuel injector...
Page 373: ...6P23H11 i 5 1 2 3 4 5 6 7 8 9 Index MEMO...
Page 375: ......
Page 376: ......