![SELVA MARINE Blue Whale 250 EFI Service Manual Download Page 337](http://html1.mh-extra.com/html/selva-marine/blue-whale-250-efi/blue-whale-250-efi_service-manual_1237213337.webp)
6P23H11
8-32
1
2
3
4
5
6
7
8
9
3.
Turn the engine start switch to ON, and
then measure the voltage within 5 sec-
onds.
4.
Measure the voltage between the termi-
nal
2
and ground, and the terminal
4
and ground as shown.
Checking the vapor shut-off valve
1.
Connect the special service tool to the
vapor shut-off valve.
2.
Apply the specified negative pressure to
the vapor shut-off valve.
3.
Check that the vapor shut-off valve
opens and the negative pressure is
released when the battery voltage is
applied to the vapor shut-off valve termi-
nals
1
.
4.
Measure resistance of vapor shut-off
valve.
Starting system
8
Checking the fuse
1.
Check the fuses for continuity. Replace if
there is no continuity.
NOTE:
For the location of the fuse, see “Fuse
holder.”
Checking the starter relay
1.
Remove the starter relay
1
and check it.
To check the relay, see “Checking the
main relay and electronic throttle valve
relay” in this chapter.
Terminal
2
–
3
:
12 V (battery voltage)
Terminal
2
– Ground:
Terminal
4
– Ground:
12 V (battery voltage)
Vacuum/pressure pump gauge set:
90890-06756
Specified negative pressure:
67 kPa (0.7 kgf/cm
2
, 9.7 psi)
S6P28400
3
2
S6P28410
4
2
Vapor shut-off valve resistance
(reference data):
30.0–34.0
Ω
at 20 °C (68 °F)
S6P28170
1
S6P28190
1
Fuel control system / Starting system
Summary of Contents for Blue Whale 250 EFI
Page 1: ...Blue Whale 250 SERVICE MANUAL...
Page 97: ...6P23H11 4 14 1 2 3 4 5 6 7 8 9 1 2 3 S6P24380 2 3 Intake manifold...
Page 111: ...6P23H11 4 28 1 2 3 4 5 6 7 8 9 MEMO Fuel injector...
Page 373: ...6P23H11 i 5 1 2 3 4 5 6 7 8 9 Index MEMO...
Page 375: ......
Page 376: ......