TRBL
SHTG
Troubleshooting
9-15
6P23H11
Troubleshooting the power unit
using the diagnostic flash indicator
1.
Connect the special service tool to the
outboard motor as shown.
NOTE:
When performing this diagnosis, all of the
electrical wires must be properly connected.
2.
Start the engine and let it idle.
3.
Check the flash pattern of the special
service tool to determine if there are any
malfunctions.
•
Normal condition
(no defective part or irregular process-
ing is found)
•
Single flash is given every 4.95 sec-
onds.
a
: Light on, 0.33 second
b
: Light off, 4.95 seconds
•
Trouble code indication
Example: The illustration indicates
code numbers 23 and 113.
a
: Light on, 0.33 second
b
: Light off, 4.95 seconds
c
: Light off, 0.33 second
d
: Light off, 1.65 seconds
4.
If a flash pattern listed in the trouble code
chart is displayed, check the malfunction-
ing part according to the flash pattern.
Diagnostic flash indicator B:
90890-06865
S6P29030E
L/W
3
1
1
b
c
a
a
a
d
d
a
a
S6P29040