2nd Edition of TEMP2000M_Series IM : April. 8. 2014 Page 98 / 176
▶
It is a screen to set the SCR output terminal, transmitting output and sub output.
▶
When the sub output is set, it can be set in [Fig. 5-2 Pattern editing screen].
Table 12-1. Output setting the 1
st
screen parameter
Parameter
Setting range
Unit
Initial data
SSR Output
Heater output, Non-use
ABS
Heater output
SCR output
Heater output, Transmission
output, Non-use
ABS
Transmission output
[Fig. 12-4] SCR output terminal and transmitting output terminal setting screen