It is a screen to set the operation termination signal and U-KEY relay.
▶
①
Setting the stationary operation, program operation termination relay and delay time operation
timeWhen the use is set for the user button, the corresponding button is displayed at the operation
screen.
☞
FIX relay: The set relay is “ON” when the stationary time set operation is terminated.
☞
PROG relay: The set relay is “ON” when the program operation is terminated.
☞
Delay time: The set relay is “ON” when the set delay time is passed.
☞
Operation time: The relay is “OFF” when the stationary or program termination signal relay is “ON”
after the set operation time is passed.
②
Setting the user button relay.
☞
Y/N for use of the button is set in [13. System initial setting]
☞
When the user button is set, the user can use the wanted relay by setting in [10. DO relay output] and
the set relay is operated when
is pressed at the screen for stationary, program stop/operation
and the corresponding button is displayed on the operation screen
③
Setting the HBA signal relay.
Table 13-10. Other signal relay setting the 3
rd
screen parameter
Parameter
Setting range
Unit
Initial data
FIX relay
0~32
ABS
0
FIX relay delay time
00.00~99.59 (MIN.SEC)
ABS
00.00
FIX relay operation time
00.00~99.59 (MIN.SEC)
ABS
00.00
PROG relay
0~32
ABS
0
PROG relay delay time
00.00~99.59 (MIN.SEC)
ABS
00.00
PROG relay operation time
00.00~99.59 (MIN.SEC)
ABS
00.00
User button output relay
0~32
ABS
0
HBA signal relay
0~32
ABS
0
*
The relay No. 13~32 can be used when I/O2 BOARD option is added.
Table 13-11. Definition of relay operation time for each signal
Signal
Condition
Relay ON time
In case of deleting the message by touching the screen
after the set relay operation time after creation.
Operation until the set relay
operation
Termination
signal
In case of deleting the message by touching the screen
during the set relay operation time after creation.
Operation until screen
touching
In case of recovery after the set relay operation time
after creation.
Operation until recovery
time
Error signal
Sensor
disconnection
signal
Standby signal
In case of recovery during the set relay operation time
after creation.
Operation until the set relay
operation
[Fig. 13-8] Other signal relay setting the 3
rd
screen
①
②
③