English Englis_
English
_49
LOGGING IN & INITIAL SETUP
DEVICE SETTING
For serial communications, confi gure devices connected to each loop. For network communications, confi gure one
connected device for each loop. (This is not available in SAMS Pro Lite.)
From the upper menu, select [System Management] > [Device Setting].
Select a [Site].
Select a [Loop].
Select a [Device Type]. Select [Controller] for access controller device, or select [Biometrics Reader] for
biometrics/fi ngerprint readers.
SSA-P102, SSA-P40x, SSA-S21xx, SSA-S30xx series products are controllers, and SSA-R20xx series products are
biometrics readers.
Select the product type for the device to be confi gured in [Product Type].
Select [Device Door Type]. Door Type varies depending on the devices.
SSA-P102, SSA-S21xx, SSA-S30xx series products are 1-door type. SSA-P40x series products are 2~4 Door type.
Select the [Device Address]. Each controller has its own address for communication.
Setting the communication address differs from product to product. For setting the device’s communication address,
refer to the product documentation for further details.
Note that communication addresses confi gured in SAMS Pro and corresponding device must match for proper
communication between them.
1.
2.
3.
4.
J
5.
6.
J
7.
J