OPERATION MANAGEMENT
In the right pane of the main screen, the Access Type search screen appears.
Provide the search criteria according to the item to fi nd.
Click Search to start searching.
In the search list, you can also add, edit or delete items. From the tool bar, click <
> to move to the input
screen. Select a searched item and click <
> to move to the deletion (change) screen. Select a searched item
and click <
> to delete it. If you want to delete multiple items at once, check all the items to delete in the search
list and click <
> to delete them all at once.
FIRE GROUP SETTING [ADD]
This function will help open the entry door by releasing the lock on the door when a [Fire Sensor] event occurs,
which is specifi ed in [System Management] > [Input Point Setting]. This feature operates using SAMS Pro and SAMS
Communication Server Pro, which may not work for the following reasons:
- If fi re events are received late because of lots of events in standby
- If the system PC is turned off or does not work
- If the communication confi guration and settings with the device are not established and specifi ed properly
- If SAMS Pro or SAMS Communication Server Pro is not activated
This is just an auxiliary means to help opening the entry door when a fi re occurs so you must install a separate
hardware equipment to let you to manually open the door in case of a fi re.
If a fi re signal event occurs, SAMS Pro will open the doors of all registered sites. This is why you must specify the
applicable entry doors by setting the fi re group.
Note that when you are setting the fi re group, you must connect the Door Lock to Relay 1 for S30xx/S210x, and
Relay 1, 3, 8, and 10 for P40x(T), and Relay 1 for P102T.
(If you want to use SSA-P40xx as a fi re group, the Door Lock should have been connected to Relay Output 1, 3, 8,
and 10.)