Example: Moving termination control
Further settings for this example:
●
[SENSe<Sensor>:]AVERage:TCONtrol
●
Every measurement is started by a trigger event. Due to the chopper phases, one
measurement lasts twice the defined aperture time. During each measurement,
the trigger synchronization is high (
). Every measure-
ment provides a result. During the settling phase, the amount of the result is
already correct, but the noise is higher. After 4 measurements, when the average
count is reached, settled data are available.
When the trigger count is reached (
), the sensor module returns
to the idle state.
1
3
4
2
5
6
7
8
1 = Start of the measurement cycle
2 = Trigger event
3 = Noninverted chopper phase
4 = Inverted chopper phase
5 = Trigger synchronization
6 = Averaged measurement result after average count is reached
7 = Measurement result before average count is reached
8 = Return to idle state after trigger count (= 16 in this example) is reached