Quick Start Guide 1313.9652.62 - 02
2.19
R&S FSQ
Preparing for Use
Connecting External Devices
➢
Press the
ENTER
key.
The list of available generators will open.
➢
Using the rotary knob, select the desired generator and activate
ENTER
by pressing the
rotary knob.
The generator list will close, and the selected generator will then appear in the
SELECT
GENERATOR
table. Simultaneously, the limits for frequency and output power which
you can set on the generator will appear in the F MIN, F MAX, P MIN and P MAX fields.
➢
Using the
U
r
key, move the selection bar to the IFC column and press the
ENTER
key.
The list of available control interfaces will appear.
➢
If the TTL interfaces from the R&S FSQ and generator are connected, select
TTL
by
using the rotary knob and then activate it by pressing the rotary knob.
➢
If no TTL interface is provided or if the TTL interfaces are not connected, select
GPIB
by
using the rotary knob and then activate it by pressing the rotary knob.
➢
Using the
U
r
key, move the selection bar to the GPIB ADDR column and press the
ENTER key.
The entry field for the GPIB address of the generator will open.
➢
Enter the GPIB address of the generator and confirm with
ENTER
.
The specified address will be added to the table.
3. Select the reference frequency for the generator:
➢
If you want to operate the generator using its internal reference, change the
GEN REF
softkey to the state
INT
.
➢
If you want to operate the generator using an external reference, change the
GEN REF
softkey to the state
EXT
.
This concludes the procedure for defining the default setting for the generator.
2.3.6.3 Activating the Generator Configuration and Setting the Output Level
To select the active generator configuration, press the
FREQUENCY SWEEP
softkey. The
FREQUENCY SWEEP
table will open, and the selection bar will be located under the
STATE
column in the
SRC 1
row.
➢
If you want to use the
SRC 1
generator configuration, insert a checkmark in the field by
pressing the
ENTER
key.
A second generator configuration can be inserted in advance by
repeating the settings in the line SRC 2. This makes it easy to switch
from one generator type to another.
Summary of Contents for FSQ series
Page 1: ...R S FSQ Signal Analyzer Quick Start Guide Quick Start Guide Test Measurement 1313 9652 62 02 ...
Page 28: ...R S FSQ 0 4 Quick Start Guide 1313 9652 62 02 ...
Page 50: ...R S FSQ Front and Rear Panel Rear Panel Connections 1 22 Quick Start Guide 1313 9652 62 02 ...
Page 110: ...R S FSQ Basic Operation Setting Parameters 4 12 Quick Start Guide 1313 9652 62 02 ...
Page 209: ...Quick Start Guide 1313 9652 62 02 R S FSQ Appendix Appendix ...
Page 210: ...Quick Start Guide 1313 9652 62 02 R S FSQ Appendix ...
Page 220: ...R S FSQ Appendix Installing Non Plug Play Printers A 10 Quick Start Guide 1313 9652 62 02 ...