![Rohde & Schwarz FSQ series Quick Start Manual Download Page 136](http://html.mh-extra.com/html/rohde-and-schwarz/fsq-series/fsq-series_quick-start-manual_1477838136.webp)
R&S FSQ
Measurements in the Time Domain
5.26
Quick Start Guide 1313.9652.62 - 02
5. By using the video trigger, elicit triggering on the rising edge of the burst and shift
the start of burst to the center of the screen.
➢
Press the
TRIG
key.
➢
Press the
VIDEO
softkey and enter
70%
.
The R&S FSQ shows a static image with the GSM burst at the start of the trace.
➢
Press the
TRIGGER OFFSET
softkey and enter
-1 ms
.
The R&S FSQ shows the GSM burst in the right-hand half of the measurement diagram.
6. Configure the power measurement in the time domain.
➢
Press the MEAS key.
➢
Press the
TIME DOM POWER
softkey.
➢
Set the
LIMITS
softkey to
ON
.
➢
Press the
START LIMIT
softkey.
➢
Using the rotary knob, move the vertical line to the start of the burst.
➢
Press the
STOP LIMIT
softkey.
➢
Using the rotary knob, move the second vertical line to the end of the burst.
The R&S FSQ outputs on screen the power during the activation phase of the burst.
Fig. 5-14 Power measurement during the activation phase of the burst
Summary of Contents for FSQ series
Page 1: ...R S FSQ Signal Analyzer Quick Start Guide Quick Start Guide Test Measurement 1313 9652 62 02 ...
Page 28: ...R S FSQ 0 4 Quick Start Guide 1313 9652 62 02 ...
Page 50: ...R S FSQ Front and Rear Panel Rear Panel Connections 1 22 Quick Start Guide 1313 9652 62 02 ...
Page 110: ...R S FSQ Basic Operation Setting Parameters 4 12 Quick Start Guide 1313 9652 62 02 ...
Page 209: ...Quick Start Guide 1313 9652 62 02 R S FSQ Appendix Appendix ...
Page 210: ...Quick Start Guide 1313 9652 62 02 R S FSQ Appendix ...
Page 220: ...R S FSQ Appendix Installing Non Plug Play Printers A 10 Quick Start Guide 1313 9652 62 02 ...