Measurements in the Time Domain
5.5.2 Measuring the Power Characteristic of Burst Signals
Because of the high time resolution of the R&S FSQ at the 0 Hz display range, the edges of
TDMA bursts can be measured precisely. The edges can be shifted to the screen area by
using the trigger offset.
5.5.2.1 Example - Measuring the Edges of a GSM Burst with High Time Resolution
Test setup:
Settings on the signal generator (e.g. R&S SMIQ):
Measurement with the R&S FSQ:
The measurement is based on the setting in section
“ Example – Measuring the Power of a
GSM Burst During the Activation Phase.” on page 5.21
1. Switch off the power measurement.
➢
Press the
MEAS
key.
➢
Press the
TIME DOM POWER
softkey.
➢
In the submenu, set the
POWER
softkey to
OFF
.
2. Increase the time resolution to 100 µs.
➢
Press the
SWEEP
key and enter
100 µs
.
3. Using the trigger softkey, shift the rising edge of the GSM burst to the center of the
screen.
➢
Press the
TRIG
key.
➢
Press the
TRIGGER OFFSET
softkey.
Frequency:
100 MHz
Level:
0 dBm
Modulation:
GSM, one timeslot activated
Signal
generator
R&S FSQ
Summary of Contents for FSQ series
Page 1: ...R S FSQ Signal Analyzer Quick Start Guide Quick Start Guide Test Measurement 1313 9652 62 02 ...
Page 28: ...R S FSQ 0 4 Quick Start Guide 1313 9652 62 02 ...
Page 50: ...R S FSQ Front and Rear Panel Rear Panel Connections 1 22 Quick Start Guide 1313 9652 62 02 ...
Page 110: ...R S FSQ Basic Operation Setting Parameters 4 12 Quick Start Guide 1313 9652 62 02 ...
Page 209: ...Quick Start Guide 1313 9652 62 02 R S FSQ Appendix Appendix ...
Page 210: ...Quick Start Guide 1313 9652 62 02 R S FSQ Appendix ...
Page 220: ...R S FSQ Appendix Installing Non Plug Play Printers A 10 Quick Start Guide 1313 9652 62 02 ...