002
FAX TEL No.
Use this to input the fax number of the CE printed on the Counter Report (UP
mode).
Note: Not used for this machine.
5816
Remote Service
001
I/F Setting
Turns the remote diagnostics off and on.
[0~2/1]
0: Remote diagnostics off.
1: Serial (CSS or NRS) remote diagnostics on.
2: Network remote diagnostics.
002
CE Call
Lets the service technician start or end the remote machine check with CSS or NRS; to do this,
push the center report key
003
Function Flag
Enables and disables remote diagnosis over the NRS network.
[0~1/1]
0: Disables remote diagnosis over the network.
1: Enables remote diagnosis over the network.
004
Communication Test
NIA
005
Device Information
NIA
007
SSL Disable
Controls if RCG (Remote Communication Gate) confirmation is done by SSL during an RCG
send for the NRS over a network interface.
[0~1/1]
0: Yes. SSL not used.
1: No. SSL used.
008
RCG Connect Time
RCG Connect Timeout
5. Service Tables
350
5
Summary of Contents for G148
Page 1: ...Model MT P2 Machine Code G148 SERVICE MANUAL 23 June 2006 Subject to change...
Page 52: ...10 Clamp 1 LCT B473 51 1...
Page 94: ...16 Set the hopper 13 in its holder Punch Unit B702 93 1...
Page 129: ...2 Preventive Maintenance 128 2...
Page 163: ...1 Open the front door 2 Pull out the internal dust filter A 3 Replacement and Adjustment 162 3...
Page 172: ...4 Development motor bracket D x 3 x 1 5 Development motor E x 4 Development Unit 171 3...
Page 237: ...3 Replacement and Adjustment 236 3...
Page 295: ...Install the paper feed unit 4 Troubleshooting 294 4...
Page 435: ...5 Service Tables 434 5...
Page 521: ...6 Details 520 6...