023
ActIPv4GateW
This SP allows you to confirm the IPv4 default gateway setting that was
used when the machine started up with DHCP. For example, if the setting
for the IPv4 gateway is "0C0A80001h" this is displayed as
"192.168.000.001".
050
1284 Compatible
Enables and disables bi-directional communication on the parallel con-
nection between the machine and a computer.
[0~1/1]
0:Off
1: On
052
ECP
Disables and enables the ECP feature (1284 Mode) for data transfer.
[0~1/1]
0: Disabled
1: Enabled
065
Job Spool
Switches job spooling spooling on and off.
0: No spooling 1: Spooling enabled
066
HD Job Clear
This SP determines whether the job interrupted at power off is resumed
at the next power on. This SP operates only when SP5828 065 is set to
1.
1: Resumes printing spooled jog.
0: Clears spooled job.
069
JobSpool Protocol
This SP determines whether job spooling is enabled or dispabled for
each protocol. This is a 8-bit setting.
0
LPR
4
BMLinks (Japan Only)
1
FTP (Not Used)
5
DIPRINT
2
IPP
6
Reserved (Not Used)
3
SMB
7
Reserved (Not Used)
090
TELNET
Disables or enables Telnet operation. If this SP is disabled, the Telnet
port is closed.
[0~1/1]
0: Disable
1: Enable
Service Program Mode Tables
359
5
Summary of Contents for G148
Page 1: ...Model MT P2 Machine Code G148 SERVICE MANUAL 23 June 2006 Subject to change...
Page 52: ...10 Clamp 1 LCT B473 51 1...
Page 94: ...16 Set the hopper 13 in its holder Punch Unit B702 93 1...
Page 129: ...2 Preventive Maintenance 128 2...
Page 163: ...1 Open the front door 2 Pull out the internal dust filter A 3 Replacement and Adjustment 162 3...
Page 172: ...4 Development motor bracket D x 3 x 1 5 Development motor E x 4 Development Unit 171 3...
Page 237: ...3 Replacement and Adjustment 236 3...
Page 295: ...Install the paper feed unit 4 Troubleshooting 294 4...
Page 435: ...5 Service Tables 434 5...
Page 521: ...6 Details 520 6...