Vsg less than 4.0V when the maximum
PWM input (255) is applied to the ID sen-
sor.
Vsg greater than or equal to 4.0V when
the minimum PWM input (0) is applied to
the ID sensor.
• ID sensor connector defective
• IOB defective
• ID sensor pattern not written correctly
• Incorrect image density
• Charge power pack defective
• ID sensor dirty
354
C
ID sensor error 5
Vsg falls out of the adjustment target (4.0
±0.2V) during Vsg checking.
• ID sensor defective
• ID sensor harness disconnected
• ID sensor connector defective
• IOB defective
• ID sensor pattern not written correctly
• Incorrect image density
• Charge power pack defective
• ID sensor dirty
355
C
ID sensor error 6
The Vp value, which measures the reflec-
tivity of the ID sensor pattern, was not in
the range of -70V to -400V.
• Potential sensor defective
• Potential sensor harness defective
• Potential sensor disconnected
• IOB defective
• OPC unit connector defective
• Charge corona power pack defective
• Charge corona wire dirty, broken
SC400: Image Development (2)
401
D
Transfer output abnormal
When the transfer is output, the feed-
back voltage remains higher than 4V
for 60 ms.
• Transfer power pack defective
• Transfer current terminal, transfer power
pack disconnected, damaged connector
4. Troubleshooting
254
4
Summary of Contents for G148
Page 1: ...Model MT P2 Machine Code G148 SERVICE MANUAL 23 June 2006 Subject to change...
Page 52: ...10 Clamp 1 LCT B473 51 1...
Page 94: ...16 Set the hopper 13 in its holder Punch Unit B702 93 1...
Page 129: ...2 Preventive Maintenance 128 2...
Page 163: ...1 Open the front door 2 Pull out the internal dust filter A 3 Replacement and Adjustment 162 3...
Page 172: ...4 Development motor bracket D x 3 x 1 5 Development motor E x 4 Development Unit 171 3...
Page 237: ...3 Replacement and Adjustment 236 3...
Page 295: ...Install the paper feed unit 4 Troubleshooting 294 4...
Page 435: ...5 Service Tables 434 5...
Page 521: ...6 Details 520 6...