0F30
0F31
ASIC (Mandolin) for system control
could not be detected. After the PCI
configuration, the device ID for the
ASIC could not be checked.
• ASCI (Mandolin) for system control is de-
fective
• Interface between North Bridge and AGPI
is defective
• Replace the mother board
0F41
The read/write check done for resi-
dent RAM on the mother board could
not be done correctly.
• Memory device defective
• Replace the mother board
50B1
Could not initialize or read the bus
connection.
• Bus connection defective, loose
• SSCG defective
• Replace the mother board
50B2
Value of the SSCG register is incor-
rect.
• Bus connection loose, defective
• SSCG defective
• Replace the mother board
834
D
Self-diagnostic error 9: Optional Memory RAM DIMM
5101
The write/verify check for the option-
al RAM chip on the engine mother
board gave an error.
• Controller defective
• Mother board defective
838
D
Self-diagnostic Error: Clock Generator
• Replace the controller board
A verify error occurred when setting data
was read from the clock generator via the
I2C bus.
839
D
Serial Flash
• Replace the controller board
A read/write operation on the Software
Status Register failed.
850
B
Net I/F error
Duplicate IP addresses.
Illegal IP address.
• IP address setting incorrect
• NIB (PHY) board defective
• Controller board defective
4. Troubleshooting
276
4
Summary of Contents for G148
Page 1: ...Model MT P2 Machine Code G148 SERVICE MANUAL 23 June 2006 Subject to change...
Page 52: ...10 Clamp 1 LCT B473 51 1...
Page 94: ...16 Set the hopper 13 in its holder Punch Unit B702 93 1...
Page 129: ...2 Preventive Maintenance 128 2...
Page 163: ...1 Open the front door 2 Pull out the internal dust filter A 3 Replacement and Adjustment 162 3...
Page 172: ...4 Development motor bracket D x 3 x 1 5 Development motor E x 4 Development Unit 171 3...
Page 237: ...3 Replacement and Adjustment 236 3...
Page 295: ...Install the paper feed unit 4 Troubleshooting 294 4...
Page 435: ...5 Service Tables 434 5...
Page 521: ...6 Details 520 6...