3.
Upper cover [B] (
x 1)
• Rotate the cover down slightly to remove.
4.
Web shafts [C] (
x 2)
5.
Remove the web cleaning rollers from the shaft driver pins [D].
6.
Web bushing [E] (spring x 1)
7.
Cleaning roller [F]
Reinstallation
• After replacing the web with a new one, you must execute SP1902-001 (Fusing Web Used Area
Display/Setting) to reset the web consumption count to zero. This SP code must be executed to release
SC550.
• Be sure to print an SMC report before executing Memory All Clear (SP5801). After executing
SP5801, be sure to re-enter the value recorded for SP1902-001 in the SMC report.