Transport, Inverter, Feed Out: Face-down
(1): From the registration sensor to the fusing unit exit, jam detection is the same as face-up feed out.
(2): Exit unit entrance sensor ON > Duplex entrance sensor does not switch OFF at the correct time.
(3): Registration sensor OFF > Duplex entrance sensor does not switch OFF at the correct time.
(4): Duplex entrance sensor ON > Inverter exit sensor does not switch OFF at the correct time.
(5): Inverter exit sensor ON > Paper exit sensor does not switch ON at the correct time.
(6):
Duplex entrance sensor OFF > Paper exit sensor does not switch OFF at the correct time. (Paper
remains at the duplex unit exit.)
4. Troubleshooting
246
4